25mm Pore Size hplc syringe filter
Acrodisc Syringe Filters - Pall
25 mm PSF Acrodisc Syringe Filters. Features a large effective filtration area for increased sample throughput, ideal for sample volumes of ≤ 125 mL. Pall’s proprietary membrane technology and accurate pore size ratings offer superior HPLC column protection, helping extend column life by as much as 52 times. Shop Now 25 mm PSF Syringe Filters.
25 mm, Acrodisc® Syringe Filter, 0.45 µm, GF/Nylon Membrane
Sample filtration using syringe filters containing 0.45 μm (HPLC) or 0.2 μm (UHPLC) pore size membranes will also extend the life of chromatography columns by preventing particulate from blocking the flow path between the column packing.
Whatman™ 25mm GD/X Syringe Filters - VWR
all common solvents used in HPLC (methanol, acetonitrile, water). It also exhibits low levels of non specific protein binding. Technical Data Whatman 25 mm GD/X Syringe Filters Dimensions: 30 mm × 21 mm Weight: Approximately 3 grams Filtration Area: 4.6 cm² Maximum Pressure: 75 psi (5.2 bar) Housing: Polypropylene Hold Up Volume: Full housing
Millex Syringe Filter, Hydrophilic PTFE - Sigma-Aldrich
Millipore. SLLGX13. Millex Syringe Filter Unit, PTFE, Hydrophilic, Non-sterile. Replaces SLLGH13NL, 0.20 µm pore size, 13 mm diameter, Millex-LG hydrophilic PTFE membrane
Glass Fiber Syringe Filter at Thomas Scientific
EZFlow 25mm High Particulate Syringe Filters are designed for high throughput filtration of viscous and particle-laden solutions. The syringe filter contains a filter membrane along with a glass fiber pre-filter. The filter membrane is available in PES or Hydrophilic PVDF materials, offered in 0.2µm
Choice™ PVDF (Hydrophilic) Syringe Filters
Specifications Membrane: HPLC certified PVDF Maximum operating temperature: 100 °C Housing: Medical grade, virgin polypropylene Autoclave: Sterilize by dry heat at 121 °C for 15 minutes Applications HPLC and organic-solvent sample preparation and clean-up Protein-based samples with high non-specific binding Environmental water samples
Millex Syringe Filter, hydrophilic PTFE - Sigma-Aldrich
Millex Syringe Filter, MCE, Non-sterile 0.45 µm pore size, 25 mm diameter, Millex-HA mixed cellulose esters (MCE) membrane, hydrophilic View Price and Availability Properties material PTFE membranepolypropylene polypropylene housing sterility non-sterile product line Millex® feature holdup volume≤ 80 μL (after air purge)hydrophilic
Syringe Filters for Chromatography - Sigma-Aldrich
10-100 mL: 25 mm. Chemical Compatibility. Broad chemical compatibility (aqueous and organic) Broad chemical compatibility (aqueous and organic) Broad chemical compatibility (aqueous) Extractables. Low extractables prevent sample contamination. Low extractables prevent sample contamination.
Syringe Filters - Sigma-Aldrich
Millex-SV 5.0 µm, A 25 mm diameter sterile syringe filter with a 5 µm pore size hydrophilic PVDF membrane. Comes in a pack of 50. 5.0 μm pore size Expand SLGVX13 Millex Syringe Filter, Durapore ® ( PVDF ), Non-sterile, 0.22 µm pore size, 13 mm diameter, Millex-GV Durapore ® ( PVDF ) membrane, hydrophilic 0.22 μm pore size Expand SLHVM33RS
Whatman™ 25mm GD/X Syringe Filters - VWR
all common solvents used in HPLC (methanol, acetonitrile, water). It also exhibits low levels of non specific protein binding. Technical Data Whatman 25 mm GD/X Syringe Filters Dimensions: 30 mm × 21 mm Weight: Approximately 3 grams Filtration Area: 4.6 cm² Maximum Pressure: 75 psi (5.2 bar) Housing: Polypropylene Hold Up Volume: Full housing
Choice™ Polypropylene (PP) Syringe Filters
Pore Size: 0.45 μm: Sterility: Non-sterile: For Use With (Application) HPLC, SPE: Housing Material: Solvent Resistent, Low-Extractable Polypropylene: No. per Pack: 100: Prefilter: No: Pressure Rating: 90 psi: Product Line: Choice: Type: Syringe Filter: Diameter (Metric) 25 mm: Unit Size: Pack of 100
Acrodisc® 25 mm Syringe Filter, 0.45 µm PVDF Membrane, 1000
Diameter (Metric) 25 mm Effective Filtration Area (Metric) 3.9 cm² Filter Media Hydrophilic polyvinylidene fluoride (PVDF) Hold-Up Volume <100 µL Housing Material polypropylene Maximum Operating Pressure (bar) 2.1 bar Maximum Operating Temperature (Metric) 82 °C Typical Flow Rate 144 mL/min at 2.1 bar (210 kPa, 30 psi) Overview Description Type Use
Choice™ Regenerated Cellulose Syringe Filters
These syringe filters provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size. Adding a syringe filtration step prior to chromatographic injection helps to ensure more consistent and reliable results, protects delicate instruments, and prolongs column life.
Nalgene™ Syringe Filters, Non-sterile
Thermo Scientific™ Nalgene™ syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications.
Thermo Scientific™ Nalgene™ Sterile Syringe Filters
Filter sample volumes of 10 to 100mL with these sterile syringe filters featuring a variety of membranes and pore sizes for most laboratory applications. $253.50 - $610.50