66 PES PTFE PVDF RC syringe filter
Syringe Filters | Low Price PES, PTFE, PVDF & Nylon Filters
PES (Polyethersulfone) Nylon; PTFE can be used with almost any solvent due to its low reactivity and low extractables. Additionally, PTFE has extremely high thermal stability, allowing for a wider range of processing temperatures compared to standard membrane materials. However, PTFE is naturally hydrophobic, which can make the filtering of aqueous solutions difficult.
Millipore® Filter Membranes - Sigma-Aldrich
AAWP04700. MF-Millipore ® Membrane Filter, 0.8 µm pore size, 47 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic, white, 100 discs. 0.8 μm pore size. 82 % porosity. Expand. GVWP04700. Durapore ® Membrane Filter, 0.22 µm, 0.22 µm pore size, hydrophilic PVDF, 47 mm membrane. 0.22 μm pore size.
Whatman Mini-UniPrep Syringeless Filters | Cytiva
Mini-UniPrep Syringeless Filter, amber housing, std cap, 0.45 µm, PVDF filtration med (100 pcs) Amber. 0.45 µm. Polyvinylidene Difluoride (PVDF) 100 pieces. 353.00 USD. Add to cart. Add to quote list. UN503NPURC.
Millex® Syringe Filters - Sigma-Aldrich
Medical Millex-GV Syringe Filter Unit, 0.22 µm, PVDF, 33 mm, gamma sterilized, A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane. Comes in a pack of 50. Expand SLGVV255F Millex-GV Filter, 0.22 µm, A 25 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane.
Syringe Filters | Corning
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
How to Select a Syringe Filter and How to Use it? (2020 Guide)
Feb 17, 2020 · A PTFE syringe filter is an ideal choice for filtering and de-gassing chromatography solvents. With proper pre-wetting (commonly used alcohol), aqueous samples are also compatible. When using air-vents, these syringe filters are capable of stopping moisture from passing through. Workable pH range: 1-14.
Syringe Filters, MCE, PVDF, PTFE, Nylon, and PES
Description. These Syringe Filters are ideal for filtering culture media and organic solvents in a wide range of applications. All items are tested for filter efficiency and housing integrity. Filter housing is manufactured and tested to withstand pressures of up to 75 PSI (5.1 Bar) Membrane materials include MCE, PVDF, PTFE, Nylon, and PES.
Phenex Syringe Filters: Phenomenex
The air is used as a purge to minimize fluid retention when expelling the sample from the syringe (Step 3 below). Step 2: Assemble Twist the luer lock end of the filter securely onto the syringe. (Caution: Do not use syringes without a matching luer lock, otherwise the pressure applied may cause the filter to come off unexpectedly.) Step 3: Filter
Titan3 and Target2 Chromatography Syringe Filters
Polypropylene syringe filters Chemically resistant membrane with low protein binding. • Hydrophilic membrane for aqueous or organic sample matrixes • Use with protein or peptide-based assays The hydrophilic polypropylene membrane is easily wetted with water and does not require pre-treatment with alcohols. Compatible with biological samples.
Syringe Filters - Axial Scientific
NYLON-66 (Polyamide) SYRINGE FILTERS WITH POLYPROPYLENE HOUSING • Hydrophilic membrane • high bubbling point • very high protein binding • resistant to most organic and aqueous solvents • low level of extractables • non-resistant to acids and aggressive filtration samples • useful for HPLC and general halogenated solvents • L.E. (Lower Extractable)
AARK Type NN66 PES PVDF PTFE hplc filter-HPLC Filter
Acrodisc PSF GxF syringe filters with glass/PTFE membrane Sciences filters with GHP, PVDF, nylon, or PES membranes. Generally, one filter type. Syringe Filters Solvent Compatibility Chart – Restek. Sodium Hydroxide 3N, 12%, N, R, R, R, R. Group of Substance & Chemical Reagents, Cellulose Acetate, Nylon, PES, PTFE, PVDF. ALCOHOLS. AARK
Rc Syringe Filter at Thomas Scientific
A syringe filter generally consists of a plastic housing with a membrane which serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter. We offer three filter diameters: 15mm, 25mm and 30mm with membranes made of the following materials: RC -.
VWR® Syringe Filters | VWR
Nonsterile syringe filters are excellent for HPLC applications Biosafe according to Class VI plastics tests Available with Nylon, PES, PTFE, PVDF, CA, RC membrane, and GF (Glass fiber) Available with hydrophilic or hydrophobic PTFE Each filter has a female Luer-lock inlet and a male slip Luer outlet
Syringe Filters for Sterile Filtration | Minisart® | Sartorius
Minisart ® PP Syringe Filters offer essential elimination of particles from the sample prior to HPLC | UHPLC | ICP-MS or other chromatographic analysis, in addition to chemically robust polypropylene housing with inert, PTFE, RC, or Nylon membrane options. Wide range of filter areas; 0.07 cm 2, 1.7 cm2 and 4.8 cm 2. Maximum chemical resistance.
Captiva Syringe Filters | HPLC | Aijiren
Captiva syringe filters offer the industry’s highest flow rates and loading capacities. Using Captiva syringe filters also significantly extends column lifetime. Choose from a variety of membrane types and pore sizes to prepare small-volume samples for High-Performance Liquid Chromatography (HPLC) and ion chromatography. Sample Filtration.