HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters
HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters

cellulose acetate 0.22 um syringe filter for hplc from Acrodisc

Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA) Qty/Pack: 100pcs/pack Application: Filter Payment: T/T MOQ: 1 pack
Inquiry Chat Now
Product Description

Corning Filtration Guide

Syringe/Disc Filters The smaller conventional Corning® syringe disc-type filters (4, 15, 25, 26, and 28 mm diameter) are used with syringes which serves as both the fluid reservoir and the pressure source. They are 100% integrity tested. The HPLC-certified non-sterile syringe filters are available with nylon, regenerated

Corning SFCA Syringe Filters :Filtration:Syringe and

Description. For tissue culture and HPLC applications. Acrylic housing. A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon

Syringe Filters, 0.22/0.45 um Disposable Syringe Filters - Hawach

Disposable Syringe Filters. The Winstar color syringe filter is designed with the color code. The maximum working pressure is 6.2bar and the filtration speed is fast. The filter structure of the standard female Luer lock and male roller accessories is adopted.

Syringe Filters for HPLC & Sample Preparation | analytics

Pore Sizes and Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are used for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm, respectively.

Solvent Compatibility Chart for Syringe Filters

Top 10 Reasons to Use Restek Syringe Filters Group of Substance & Chemical Reagents Cellulose Acetate Nylon PES PTFE PVDF ACIDS Acetic, 5% L R R R R Acetic, 10% L R R R R Acetic, 25% N L R R R Acetic, Glacial N N R R R Boric - L - R - Formic 25% L N - R - Hydrochloric 15% L L R R L Hydrochloric 25% N N R R - Hydrochloric concentrated N N L R N

Syringe Filter, Cellulose Acetate, 0.22um, 30mm

These high-quality syringe filters are designed to be low protein binding for reduced extractables and low hold-up volume. To be used in: Filtration of aqueous solutions such as buffers, media and reagents; HPLC

Syringe Filters | VWR

Description: Acrodisc® MS syringe filters are available in 13 and 25mm diameters with 0.2µm rated WWPTFE membrane and HDPE housings. ,CA30621-078PK,CA89194-420PK Mustang XT Acrodisc® Syringe Filters , Pall Laboratory

Syringe Filters for HPLC and sample preparation | analytics

Pore Sizes and Pore Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are usually for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm

Syringe Filters - Fisher Sci

Syringe Filters Sartorius™ Minisart™ NML Syringe Filter, Nonsterile Provides fast and reliable filtration of small to medium volumes, complete with ready-to-connect filter units.

High quality wheel filters nylon syringe filter for hplc acrodisc

nylon membrane filter for sale syringe filters Versapor® merane, diam. 25 mm . These offer high quality filtration for analytical samples. Certified for HPLC to ensure low extractables. Available in a broad range of meranes to meet sample compatibility requirements. The 25 mm Acrodisc is recommended for sample volumes from 5 to 100 mL.

Syringe Filters for Sterile Filtration | Minisart® | Sartorius

The GF prefilter protects the membrane filter from early clogging and increases total throughput. Two different setups are available. One with acrylic-based housing and SFCA (surfactant-free cellulose acetate) membrane is designed for aqueous and oily solutions.

Corning® 431205 Sterile 1000mL Vacuum Filter Unit with 0.22µm

This new vacuum filter/storage bottle system is designed for filtering and storing cell culture media, biological fluids, and other aqueous solutions. The new system consists of a 1000mL polystyrene receiver bottle and a 500mL filter funnel with a 0.22µm pore size 54.5cm2 area CA membrane and a polyethylene neck adaptor with hose connector. Cellulose acetate (CA) membranes provide fast flow

0.22 Micron Syringe Filters - Samples Available - Ships Next

Cellulose Acetate CA Syringe Filters, 0.22 um, 33mm, Luer-Lok/Luer Slip, Sterile, 100 per pack, SF14495 Regular Price: $175.95 Price $153.00

How to Choose Right Syringe Filter -- Filter Membrane Materials

Cellulose Acetate (CA) Cellulose acetate is a very low protein binding membrane that is ideal for aqueous based samples and biological samples. It is a lower protein binder than either polyethersulphone or PVDF membranes, but has a lower chemical resistance than regenerated cellulose (RC).

VWR® Syringe Filters | VWR

Syringe filters with cellulose acetate or polyethersulfone membranes are ideal for sterile filtration of buffers, tissue culture media or additives, and other biologicals. The polyethersulfone membrane offers high flow rates. Nonsterile syringe filters are excellent for HPLC applications.

GVS, Syringe Filters, Cellulose Acetate Filters, 0.22um

Cell Acetate Syringe Filter 0.22um Sterile 25 mm pk50 Your Price: €43.95 FIL6614 Cell Acetate Syringe Filter 0.45um Sterile 25 mm, pk50 Your Price: €43.95 FIL6668 Sartorius Minisart RC 25mm x 0.2um, pk 50 Your Price: €135.32 FIL6604

Cameo 30 mm Cellulose Acetate Syringe Filters | |

The 0.22 µm membrane is the filter of choice for sterile filtration of aqueous solutions such as nutrient media, buffers and sera. The 0.45 m membrane is a very convenient filter type for the reduction of particles and microorganisms in aqueous solutions such as nutrient media, buffers and sera.

Minisart Syringe Filters The Easy Choice – Clean and Safe

Cellulose Acetate 28 mm for up to 200 ml PES Polyethersulfone 0.2 μm 25 mm for up to 100 ml All Aqueous Solutions Tissue Culture Media UHPLC, etc. (Columns < 3 μm Particles) Bacteria 1 – 100 ml RC Regenerated Cellulose 0.45 μm 15 mm for up to 15

MF-Millipore™ Membrane Filter, 0.22 µm pore size |

MF-Millipore Membrane Filter, 0.22 µm pore size 47 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic, white, 100 discs - Find MSDS or SDS, a COA, data sheets and more information. Description Catalogue Number GSWP04700 Trade Name

SYRINGE FILTERS 0.45 | Sigma-Aldrich

Search results for SYRINGE FILTERS 0.45 at Sigma-Aldrich System Maintenance Alert: Due to planned maintenance of our internal systems, web functionality including order placement, price and availability checks and SDS display will not be available for Asia

PES Syringe Filters - Non-Sterile Syringe Filters

PES Syringe Filters, Acrodisc® Syringe Filter with Supor® Membrane - 0.1 µm, 25 mm modified acrylic housing (1000/pkg)PES Syringe FiltersNon-Sterile Syringe Filters Pall Corporation is a filtration, separation and purification leader providing solutions to meet the

Shimadzu Scientific US Webstore - Syringe Filter, 13mm

Syringe Filter, 13mm 0.22um Cellulose Acetate 100pk Red, luer lock E-mail this product to a friend Syringe Filters Material: with Luer Lock Inlet • Luer lock inlet offers leak-tight syringe connection. • Variety of filter types, porosities, and diameters. • Color coded for

Syringe Filters - Fisher Sci

Filter Holders and Hardware Filter Paper Filtering Funnels Food and Beverage Testing Glass Fiber Filters and Prefilters Membranes for Filtration Syringe and Syringeless Filters

cellulose acetate filter | Sigma-Aldrich

Search results for cellulose acetate filter at Sigma-Aldrich System Maintenance Alert: Due to planned maintenance of our internal systems, web functionality including order placement, price and availability checks and SDS display will not be available for Asia and

Target2™ Cellulose Acetate Syringe Filters

Target2 Syringe Filters are an ideal choice for general purpose laboratory use. Robust and reliable, they deliver excellent performance at an attractive price. Outstanding Performance Low extractable membranes and housings ensure that no filter-borne contaminants

Syringe Filters for HPLC & Sample Preparation | analytics

Pore Sizes and Volumes The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are used for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm, respectively.

0.22 um Syringe Filters, Sterile Syringe Filters

Sterile Syringe Filters Hawach Scientific’s sterile syringe filters are available in wide variety of filter membrane materials, pore sizes and diameters for different applications and sample volume. The available materials include PTFE, PP, PVDF, Nylon, PES, MCE, CA, and glass fiber, they are constructed with virgin polypropylene and welding to prevent leak of the sample solvent.

Cellulose Acetate Syringe Filters, Sterile, Abluo, 0.22

Cellulose Acetate Syringe Filters, Sterile, 0.22 Micron, 25mm, 50/pk Product code CAS022550 . Sterlitech will be closed Friday, July 3 in honor of US Independence day. Click here if you need to contact us

Syringe Filters | Thermo Fisher Scientific - US

Syringe Filter Application Premium Brand Routine Brand Basic Brand Titan3 Nylon Target2 Nylon Choice Nylon General laboratory filtration Filtration for most HPLC samples Titan3 PTFE (Hydrophobic) Target2 PTFE (Hydrophobic) Choice PTFE (Hydrophobic)

Cellulose Acetate Membrane Syringe Filters - Syringe

Sigma-Aldrich Online Catalog Product List: Cellulose Acetate Membrane Syringe Filters System Maintenance Alert: Due to planned maintenance of our internal systems, web functionality including order placement, price and availability checks and SDS display will

Inquiry
Send on email.all fields width on * are required. Please enter your question and contact information.we will get back to you as soon as possible!