HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters
HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters

Common use 0.2 um ptfe membrane filter for hplc acrodisc

Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA) Qty/Pack: 100pcs/pack Application: Filter Payment: T/T MOQ: 1 pack
Inquiry Chat Now
Product Description

Syringe filter - Wikipedia

In scientific applications, the most common sizes available are 0.2 or 0.22 μm and 0.45 μm pores. These sizes are sufficient for HPLC use. The smallest known sterile syringe microfilter have pore sizes of 0.02 μm. Membrane diameters of 10 mm, 13 mm, 25 mm are common as well. Some syringe filters for small volumes may not resemble a wheel at all.

Thermo Scientific™ Target2™ PTFE Syringe Filters PTFE Syringe

Target2 Syringe Filters are an ideal choice for general purpose laboratory use. Robust and reliable, they deliver excellent performance at an attractive price. Outstanding Performance. Low extractable membranes and housings ensure that no filter-borne contaminants are added to your sample; Performance-tested under actual HPLC conditions

Acrodisc PSF Syringe Filters - Pall Corporation

PTFE, Nylon, PVDF or wwPTFE membrane to be low in UV absorbing extractables. They have been tested for compatibility with common HPLC solvents (water, acetonitrile and methanol) using established HPLC procedures. Filtrate from a statistically significant sampling of Acrodisc PSF syringe filters was collected

Laboratory Filters | Filtration Products | Waters

The minispike outlet, available on 13 mm PTFE, Nylon, GH Polypro, and PVDF Acrodisc Syringe Filters, allows for easy dispensing into autosampler vials. Membrane Design Typically, the first step in selecting a suitable filter is to choose a membrane that is chemically compatible with the sample (see table below for a full selection of mebranes).

Acrodisc at Thomas Scientific

Requirements of Mobile Phase Filtration Membranes are identical in composition and quality to those used in Pall’s HPLC-certified Acrodisc® syringe filters HPLC certification assures that the filters will not add artifacts to your analysis GH Polypro membrane is the best

Corning Filtration Guide

biological fluids and gases is usually done with 0.2 or 0.22 µm pore filter membranes. Clarification and prefiltration of solutions and solvents is best accomplished with 0.45 µm or larger filter membranes. Prefiltration to improve filter performance can also be accomplished by the use of glass fiber prefilters that can be purchased separately.

Acrodisc Syringe Filters with PTFE Membrane, Pore Size 0.2 um

Acrodisc Syringe Filter with PTFE Membrane, Minispike Outlet Connection, 0.45 um Pore Size, 13 mm Diameter, 1000/Package Part #: PALL-4555 List: $2,036.00 $1,833.80

Syringe Filters for HPLC and sample preparation | analytics

Pore Sizes and Pore Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are usually for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm

Acrodisc® Syringe Filters with PTFE Membrane - 0.2 µm, 13mm

Acrodisc® Syringe Filter with PTFE Membrane - 0.2 µm, 13mm, minispike outlet (100/pkg 300/cs) “Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications.

Acrodisc Syringe Filters - pall.com

4423 Acrodisc CR PTFE, 0.2 µm, 13 mm 100/300 4553 Acrodisc CR PTFE Minispike, 0.45 µm, 13 mm 100/300 4422 Acrodisc CR PTFE, 0.45 µm, 13 mm 100/300 4225 Acrodisc CR PTFE, 0.2 µm, 25 mm 50/200 4219 Acrodisc CR PTFE, 0.45 µm, 25 mm 50/200 4226 Acrodisc CR PTFE, 1 µm, 25 mm 50/200 4484 Nylon Acrodisc, 0.45 µm, 4 mm 250/750 4550 Nylon

How to Choose Right Syringe Filter -- Filter Membrane Materials

PTFE membranes are chemically resistant to nearly all solvents, acids and bases. The membrane has low extractable and good thermal stability. PTFE is hydrophobic and requires pre-wetting prior to use with aqueous solvents. Membrane: HPLC certified PTFE, with polypropylene support; Use with: Aggressive solvents, strong acids, alcohols, bases

Pharmaceutics | Free Full-Text | Nanoporous Silica Entrapped

This study aims to examine the contribution of nanoporous silica entrapped lipid-drug complexes (NSCs) in improving the solubility and bioavailability of dutasteride (DUT). An NSC was loaded with DUT (dissolved in lipids) and dispersed at a nanoscale level using an entrapment technique. NSC microemulsion formation was confirmed using a ternary phase diagram, while the presence of DUT and lipid

HPLC Mobile Phase Filtration Kit | Pall Shop

PTFE membrane provides the ultimate in chemical compatibility for filtering harsh chemicals and HPLC mobile phases “Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications.

Acrodisc® PSF Syringe Filters, Pall Laboratory | VWR

The new Acrodisc® One and Acrodisc® PSF premium syringe filters combine the benefits of a multi-layered prefiltration device with an automation-certified filter housing.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or

Acrodisc® Syringe Filters with PTFE Membrane - HPLC/UHPLC

Acrodisc® Syringe Filters with PTFE Membrane Product image is a representative example for illustration purposes actual image may vary. Exceptional Chemical and

Inquiry