Common use 13mm ptfe membrane filter for hplc USA
Hydrophilic Membrane Filter at Thomas Scientific
13 mm filters to ensure maximum sample recovery. Easy to Identify The color-coded band on the Millex housing clearly indicates which membrane is inside. Automated, Compliant Manufacturing Process The 13 mm Millex filter manufacturing process is fully automated from membrane cutting
Filter Membranes from Cole-Parmer
When choosing a filter membrane for an application, consider several factors. Certain membrane materials are superior for different applications. The size of the particles you are attempting to separate will dictate the membrane pore size. Membrane pore sizes range from 0.10 mm to 5.00 mm.
Syringe Filter Selection for HPLC or LC/MS samples
Nov 15, 2014 · To filter samples between 1 ml and 10 ml, the 13 mm diameter filter provides a good balance between hold-up volume and large filter surface area. Larger sample volumes from 5 ml to 50 ml are often filtered through the more common 25 mm diameter filters (~4 times the filtration area as a 13 mm disc).
Syringe Filter 0.22 at Thomas Scientific
Nest syringe filters have pore size either 0.22μm or 0.45μm, and diameter 13mm or 25mm, with membrane materials either with PES or PVDF membranes. For sample volumes of 2mL to 100mL Retention volume <115µL Maximum operating temperature: 100°C autoclave at 125°C
Mobile Phase Filtration - Laboratory | Pall Corporation
We offer several filters to accommodate the various types of HPLC solvents. Our wwPTFE (water wettable polytetrafluoroethylene) membrane is a universal solvent membrane to reduce confusion with filter selection. Typical membrane filters range in size from 25 to 90 mm in diameter and are available in a 0.2 or 0.45 μm membrane pore size.
Whatman® PTFE membrane filters PTFE membrane circles, (TE 35
Chemically stable and inert: PTFE is the membrane of choice for use with aggressive solvents, liquids, and gases that can attack other membranes. It is resistant to most acids, alkalis, and solvents. Applications: One of the major applications for the PTFE membrane is the clarification of corrosives, solvents, and aggressive fluids. This includes the important requirement in HPLC analysis for sample filtration where any solid particles can cause permanent damage to the column.
Laboratory Syringe Filters | Foxx Life Sciences – shopfls
Additionally, each syringe filter is made with USP Class VI components to guarantee the quality of your results. Browse through and learn more about our syringe filters below. If you didn't find what you're looking for or if you have questions, please email us at sales@foxxlifesciences.com or call 1-603-890-3699.
Filter 0.3 at Thomas Scientific
aqueous and organic solvents used in HPLC. Since the filter is optically clear when wet it is ideally suited for culture and microscope examination of cells/particles captured on the filter surface without requiring a separate step to render the filter optically clear. Note: This membrane may
Hplc Solvent Filter at Thomas Scientific
HPLC Glass Fiber (GF) – Can be used as preliminary filtering step and for solution clarification without clogging Pre-filtration of heavily contaminated aqueous solvent based samples Extends membrane life when filtering viscous solutions Syringe Filter (PES)
Syringe Filters | Sorbent Technologies, Inc.
CHROMAFIL disposable syringe filters are used for filtration of suspended matter from liquid samples (1–100 mL). The filter can be used for sample preparation for HPLC, GC, ICP, AAS, TOC, DOC, IR, NMR, photometry, and spectroscopy samples to filter out contaminants and extraneous particles that can affect analytical results or clog liquid pathways, frits, etc.
Syringe filter - Wikipedia
In scientific applications, the most common sizes available are 0.2 or 0.22 μm and 0.45 μm pores. These sizes are sufficient for HPLC use. The smallest known sterile syringe microfilter have pore sizes of 0.02 μm. Membrane diameters of 10 mm, 13 mm, 25 mm are common as well. Some syringe filters for small volumes may not resemble a wheel at all.
Whatman filters, membranes, and devices - Cytiva
Wide range of Whatman filters, paper filters, membranes, syringes, and other devices for manual filtration or automated filtration for research, quality testing and environmental monitoring.
17mm syringe filter, syringe filter - Membrane Solutions
Membrane Solutions’new 17mm syringe filters have color-coding housings providing easy identification of membrane and porosity. Their enhanced luer-lock inlet provides secure connections and eliminates filter 'blow-off'. 17mm syringe filters supplied Nylon, PTFE, PES, MCE and PVDF which available in 0.22um, 0.45um pore sizes. 17 mm syringe filters (upper) offer up to 70% more filtration area
Microsolv Technology Corporation - MTC-USA
As a resource for you, our Technical Support is effective, easy to use and available 24 hours a day through our online Resource Center or you can contact our highly experienced Support Team directly between the hours of 9:00AM and 5:30PM Eastern Time.
Filtration for HPLC Sample Preparation - Fisher Scientific
RC available in 13 mm and 25 mm diameters; hold-up volume < 25 µL for 13 mm and < 100 µL fo r 25 mm Available in non-RC membrane types to support a variety of other applica tions Preventive care: Puradisc lters Typical data Puradisc Syringe Filters 4 mm diameter* 13 mm diameter 25 mm diameter 30 mm diameter*