Common use hydrophilic ptfe membrane filter for hplc corning
Corning™ SFCA Syringe Filters - Fisher Sci
Description. For tissue culture and HPLC applications. Acrylic housing. A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon
Kinesis Hydrophilic PVDF Membrane Filters
Product Categories: Syringe Filters, Hydrophilic PVDF: Short Description: KX Membrane Filter, Hydrophilic PVDF, 13mm, 0.45µm • Application: UHPLC & HPLC
How to Select a Syringe Filter and How to Use it? (2020 Guide)
Browse All PTFE Syringe Filters >> PVDF Hydrophilic Syringe Filters 0.22um or 0.45um . Hydrophilic PVDF (Polyvinylidene Fluoride) is an optimal choice for protein-based samples with high non-specific binding, HPLC (High Performance Liquid Chromatography) and UHPLC (Ultra HPLC).
Ptfe Membrane 0.2 at Thomas Scientific
PTFE membrane is a thin, highly porous film that behaves as an absolute retentive membrane. Their inherently hydrophobic nature make PTFE membranes ideal for applications such as filtering gases, aqueous aerosols, protecting vacuum pumps, or sterile venting fermentation tanks.
Syringe Filters for Aqueous Solutions - Support
Hydrophilic PTFE (Polytetrafluoroethylene) – strong membrane can handle high temperature liquids, excellent flow rates, low protein binding, high loading capacities, compatible with most bases, acids and solvents, PTFE ideal for aqueous, organic, or gaseous samples, PTFE multilayer filter ideal for aqueous and organic samples, cannot be used
0.45 Ptfe Filter at Thomas Scientific
Filter aggressive chemicals, including acids and non-aqueous solvents, such as those used in GC and HPLC with the Thermo Scientific™ Nalgene™ 50mm Inline Syringe Filter with PTFE membrane. Also for sterile filtration of air and gases.
Membrane Filters You Need To Know And Their Properties - ZOBUZ
Apr 23, 2020 · Nylon membrane filters are made by impregnating a polyester fiber web with a polymer made of nylon. This makes the membrane durable, heat-resistant and essentially hydrophilic. Because it is hydrophilic, it is suitable for alcohol and aqueous samples. The membrane filter can be used to sterilize, filter and clarify organic aqueous solutions
Syringe Filter Efficiency on HPLC Column Life - Membrane
Using Membrane Solutions syringe filters with GHP (hydrophilic polypropylene) membrane is the most efficient way to remove particulate and prolong the life of HPLC system components. Membrane Solutions’ syringe filters with GHP membrane are widely used for this purpose. The average retention efficiency of 0.45 µm rated syringe filters with
Filtration for HPLC Sample Preparation
use for your sample preparation. The RC membrane is broadly compatible wit h common HPLC sample solvents and mobile phases. Improve e ciency with ready-to-use products RC products are supplied r eady for use. The hydrophilic, low-protein binding RC membrane is suitable for a wide vari ety of HPLC applications. Solvent compatibility Qualities
Syringe Filter, Membrane Filter FQA - filtration solutions
The common membranes used for gas/air filtration are our hydrophobic Polypropylene and PTFE Membranes. They both inhibit the flow of water vapors (hydrophilic) while allowing regular air molecules (such as oxygen) to pass. For the PTFE membrane the water intrusion pressure (which is inversely related to pore size) is greatest with the smaller
Membrane Filter - an overview | ScienceDirect Topics
Using a custom fabricated cellulose acetate membrane, Ryu et al. created a further type of coculture system where cells on either side of the membrane were in much closer contact through the membrane pores. 74 The porosity of the membrane was shown to be greater than 50%, while the membrane thickness was less than 500 nm for all the pore diameters fabricated (0.1-, 0.4-, and 0.9-µm).
Main Applications Of Hydrophobic And Hydrophilic PTFE
Hydrophobic PTFE membrane filter can be used for atmospheric filtration detection, usually only for air filtration. Uncommon hydrophobic membranes can also be used to filter certain organic solvents, such as ethanol. In actual use, liquids that can pass hydrophobic filtration can also pass hydrophilic filtration.
How to Choose Right Syringe Filter -- Filter Membrane Materials
PTFE membranes are chemically resistant to nearly all solvents, acids and bases. The membrane has low extractable and good thermal stability. PTFE is hydrophobic and requires pre-wetting prior to use with aqueous solvents. Membrane: HPLC certified PTFE, with polypropylene support; Use with: Aggressive solvents, strong acids, alcohols, bases
Syringe Filters for HPLC/HPLC Mobile Phase Filtration - Support
PTFE Syringe Filters are universal filters that are inert to a wide variety of aggressive solvents and strong acids and bases. These syringe filters can also be exposed to high temperatures and are an excellent choice for HPLC sample preparation. We offer PTFE syringe filters in both their hydrophobic and hydrophilic states.
Syringe Filters
Polypropylene (PP) syringe filters are designed for aqueous or organic solutions that have high levels of debris and for difficult-to-filter solutions. It's a hydrophilic membrane with a wide range of chemical compatibility with organic solvents.