Common use hydrophilic ptfe membrane filter for hplc millipore
SLCR033NK Millipore Millex Syringe Filter, Hydrophilic PTFE
Millex Syringe Filter, Hydrophilic PTFE, Non-sterile: Background Information: SLCR033NS: 50 per pack SLCR033NB: 250 per pack SLCR033NK: 1000 per pack HPLC-certified for low levels of UV-absorbing extractables. Applications: Sample Filtration Prior to UHPLC, HPLC, LC-MS, and Mass Spec; Solvent Filtration; Clarification of Aqueous and Organic Solutions
Membrane selection guide - SlideShare
Sep 14, 2014 · Membrane selection guide 1. 6 Membrane Selection Guide Nylon CA(Cellulose acetate) • Hydrophilic property • Ideal for aqueous(Non-acidic) or organic sample • High protein binding, Not used when protein recovery is important, Commonly used to for general lab filtration of HPLC Reference Chart of Membrane Filter • Naturally Hydrophilic • Low protein binding suitable for aqueous samples
Millipore SLCR013NL Inline Filter Hydrophilic PTFE
Nylon filters provide broad chemical compatibility for use with aqueous and organic solutions. Millipore Express Plus (PES) filters have the fastest flowrates and higher throughput. Hydrophobic PTFE filters have excellent solvent resistance and are ideal for HPLC sample preparation.
Difference between hydrophilic and hydrophobic filters
Hydrophilic filters can be wetted with virtually any liquid, and are the preferred filters for aqueous solutions, as appropriate by compatibility. Once wetted, hydrophilic filters do not allow the free passage of gases until the applied pressure exceeds the bubble point and the liquid is expelled from the pores of the membrane.
HPLC Syringe Filter, Nylon/Hydrophilic PVDF Syringe Filter
Nylon membrane, hydrophilic, high protein binding, suitable for protein-free aqueous and organic solutions, resistant to alcohol and DMSO. PES Polyethersulfone resin membrane, hydrophilic, low protein binding, high flow rate, high porosity, not resistant to organic solvents and strong acid-base solutions, suitable for filtering cell culture media.
Membrane Filter - Autosampler Vial, Hplc Vial, PTFE Silicone
47mm PTFE Hydrophilic Membrane 0.22um. 100pcs/pk. Typically used for HPLC, microbiology, medical/clinical, and general filtration ... Millipore Membrane Filter.
Contamination Monitoring - Fisher Sci
LCr Filter 0.45 50 SLCRM25NS PVDf Membrane with Glass fiber Prefilter Description Filter Pore Size (µm) Qty/Pk Catalogue No. Millex-HPF HV Filter 0.45 50 SLHVM25NS Millex-HPF HV Filter 0.45 200 (8 x 25) SLHVMZ5NZ HPLC-Certified Millex Filters The nylon and hydrophilic PTFe Millex units are certified for HPLC analysis.
MilliporeSigma Millex Samplicity Filters, Hydrophilic PTFE
MilliporeSigma™ Millex Samplicity™ Filters, Hydrophilic PTFE To be used with the Samplicity Filtration System. Powered by vacuum, the system takes minimal manual effort to filter 1 to 8 samples into standard HPLC vials in seconds, with higher recovery than syringe filters provide.
Membrane Filtration: Choosing the Correct Type of Filter | Cytiva
Extractables are a common symptom of membrane-sample incompatibility and affect sensitive downstream analytical techniques, such as ultra-high-performance liquid chromatography (UHPLC) and high-performance liquid chromatography (HPLC). PTFE, polyvinylidene difluoride (PVDF), and RC are compatible with a wide range of solvents commonly used in
Millex Syringe Filter, Hydrophilic PTFE, Non - EMD Millipore
Millex Syringe Filter, Hydrophilic PTFE, Non-sterile, THIS ITEM WILL BE REPLACED BY SLCR033NB Replaced by SLCR033NB, 0.45 µm pore size, 25 mm diameter, Millex-LCR hydrophilic PTFE membrane - Find MSDS or SDS, a COA, data sheets and more information.
Millex Syringe Filter, Hydrophilic PTFE - Merck Millipore
Millex Syringe Filter, Hydrophilic PTFE, Non-sterile Replaces SLCR025NS & Z227412, 0.45 µm pore size, 33 mm diameter, Millex-LCR hydrophilic PTFE membrane - Find MSDS or SDS, a COA, data sheets and more information.
Pvdf Membrane Filter Millipore - Autosampler Vial, Hplc Vial
Product name. PVDF Membrane Filter Millipore. Diameter. 13mm, 25mm, 47mm and 90mm available. Pore Size. 0.22um and 0.45um. Filter Material. PVDF Hydrophilic and PVDF Hydrophobic
PTFE capsule filter – Membrane Solutions
Depth Filter PP Pleated cartridge filters PolyPure®Classic PolyPure®AB High Flow cartridge filters 600 FlowPure®-HF Melt Blown Filters MicroPure®Classic String Wound Filters AqurePure Classic KleenPure®Swimming and Spa Filter Membrane Filter PTFE membrane cartridge filter FluorPure® FluorPure®-EV AFS-Pure® PFA PES membrane cartridge
EMD Millipore SLLG025SS General Purpose Syringe Filter, LCR
Millipore syringe filters are available in a variety of membranes and housing styles to meet your application needs. Ideal for sterile, ion chromatography, and HPLC sample preparation. All syringe filters have a female luer-lock inlet and a male luer slip connector.
PTFE Membrane Filters, 0.22 Micron Hydrophobic Membrane
The PTFE membrane has hydrophobic properties and can filter out water in air and gas. As an absolute retentive membrane, hydrophobic PTFE membrane filters have excellent corrosion resistance and high flow rate, which are equivalent to Millipore membranes. Thin, highly porous, our PTFE disc has OEM service and their sizes could be customized.