Common use hydrophobic ptfe filters for hplc whatman
Syringe Filters for HPLC & Sample Preparation | analytics
Pore Sizes and Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are used for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm, respectively.
PTFE Syringe Filters, 0.45μm, 25mm, Hydrophobic, Non-sterile
All the syringe filters are HPLC certified. Hydrophobic PTFE syringe filters have broad chemical compatibility, high pH resistance.. They are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation.
Membrane Filters for Lab Filtration | analytics-shop.com
PTFE membranes are extremely resistant to aggressive solvents and acids and can be used to filter particulate from both liquid and gas samples. Regenerated Cellulose (RC) Regenerated cellulose membranes are resistant to solvents and are hydrophilic. 0.45 μm pore size is typically used for HPLC sample preparation.
Laboratory filtration
Membrane filters are generally described as screen filters because particles are almost entirely trapped on the filter surface. The narrow effective pore size distribution of Whatman membrane filters is one of their major features. Whatman cellulose filter papers exhibit particle retention levels down to 2.5 µm.
Syringe Filters - Non Sterile Syringe Filters - Wyvern Scientific
Hydrophobic PTFE syringe filters have broad chemical compatibility, high pH resistance.. They are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation. The Pure polypropylene housings are color-coded and available in smooth rim or gear rim formats.
Whatman 10463533 PTFE ReZist Syringe Filter for HPLC, 30mm, 5
The Whatman ReZist syringe filter has been specifically designed to be resistant to organic solvents. The filter contains a hydrophobic PTFE membrane laminated with polypropylene. The filter provides first class chemical resistance against usual organic HPLC solvents. Inlet/Outlet: Luer-Lock Female/Luer Male. PTFE. 30mm. 5.0µm. 100/Pack.
Whatman PTFE Membrane Filters - Camlab
The 0.45µm pore size is normally used for HPLC applications. Air and gas sterilization make use of the hydrophobic characteristics of PTFE membrane filters and their ability to stop aqueous aerosols. Pore sizes of 0.2µm and 0.45µm are typically used in these tasks.
Membrane Filters, Whatman WTP (PTFE) | General Laboratory
One of the major applications for the PTFE (Type WTP) filter is the clarification of corrosives, solvents and aggressive fluids. This includes the important requirement in HPLC analysis for sample filtration where any solid particles can cause permanent damage to the column. The 0.5µm pore size is normally used. Air and gas sterilization make use of the hydrophobic characteristics of PTFE
Whatman PFTE Membrane Filters ‒ TE Range | Cytiva, formerly
Whatman PTFE membrane filters from Cytiva's business are chemically stable and inert, making them suitable for use with aggressive organic solvents, strong acids, and alkalis. The TE range features polypropylene support material for improved strength and handling Temperature resistant up to 120°C
Whatman™ 7585-004 Grade WTP Plain White PTFE Membrane Filter
The 0.5 µm pore size PTFE membrane filter is normally used in HPLC analysis for sample filtration where any solid particles can cause permanent damage to the column. Whatman™ Grade WTP PTFE membrane filters are an excellent choice for use with aggressive solvents liquids and gases that can attack other membranes.
Whatman™ Puradisc™ 25 TF Disposable Filter Device
Do not use internally or externally in humans or animals. Puradisc 25 TF disposable filter devices have been designed to provide pure filtration of solvents, chemicals and non-aqueous solutions and samples. They consist of a PTFE membrane with a polypropylene housing. Disposable filtration devices provide great labor saving efficiency while
Syringe Filters - Fisher Scientific
Syringe Filters Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ 30mm Puradisc™ FP Nonsterile Cellulose Acetate Syringe Filters Exhibit very low protein binding, so they are suitable for protein recovery applications.
Whatman ® PTFE membrane filters - Sigma-Aldrich
Whatman ® PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. The hydrophobic nature of the membrane also has applications for air and gas sterilization.
Whatman ® PTFE membrane filters - whatman filter
Whatman ® PTFE Membranes Whatman PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids, and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. The hydrophobic nature of the membrane also has applications for air and gas
Syringe and Syringeless Filters - Fisher Sci
Syringe and Syringeless Filters; Syringe and Syringeless Filters 1 – 30 1132 . Interest Areas. Life Science