Common use hydrophobic ptfe membrane filter for hplc phenomenex
UHPLC/HPLC Sample Filtration 2. characteristics of your
filter for most applications. Ptfe Polytetrafluoroethylene(PTFE) - Phenex-PTFE membranes are inherently hydrophobic and excellent for filtration of 100 % organic or highly acidic or basic samples. Pes Polyethersulfone(PES) - Polyethersulfone membranes exhibit very fast-flow and ultra-low protein binding characteristics and are ideally suited
GEnERAL LABORATORY COnSUMABLES - Phenomenex
Widely used for (PTFE, Teflon®) chromatography, and for clarification of non-aqueous samples. Although this membrane is hydrophobic, it can be made hydrophilic by wetting the membrane with alcohol and then flushing with deionized water. Phenex™ SYRINGE FILTERS For HPLC and GC sample and solvent filtration
HPLC ACCESSORIES - Phenomenex
Recommended filter membranes: Nylon 66® is a highly resistant material and can be used with almost all laboratory solvents. Since Nylon 66 is hydrophilic, no prewetting of the filter is required. PTFE (Teflon®)membrane filters are excellent for organic or other aggressive solvent systems. Extremely low levels of extractables
Fluoropore™ and Omnipore™ PTFE Membrane Filters | Sigma-Aldrich
Polytetrafluoroethylene (PTFE) membrane filters, with their broad chemical compatibility, are versatile filters for general clarification. Choose Fluoropore™ Hydrophobic PTFE Membrane Filters for filtering organic-based liquids or gases, and choose and Omnipore™ Hydrophilic PTFE Membrane Filters for filtering aqueous solutions.
Universal Hydrophilic Syringe Filters: Millex® Hydrophilic PTFE
Millex® hydrophilic PTFE syringe filters boast broad chemical compatibility and are HPLC-certified, guaranteeing low extractables. With their robust performance, these filters can be used for a variety of samples without the risk of membrane failure or sample contamination.
Minisart® SRP15 Syringe Filter 17574----------Q, 0.45 µm
Minisart® SRP15 Syringe Filter 17574-----Q, 0.45 µm hydrophobic PTFE Minisart ® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17574 with a pore size of 0.45 µm can be used for sample preparation.
Filter Validation Studies for Pharmaceutical QC – Factors
Naproxen dissolved in phosphate buffer (pH 7.4) was filtered through a 0.45 µm hydrophilic PTFE Millex ® syringe filter. This study was also conducted with 0.2 µm Millex ® hydrophilic PTFE syringe filters, with very similar results obtained (Figure 2). Membrane pore size did not significantly impact naproxen saturation of syringe filters.
Filtration - phenomenex.belvr.by
Prefiltration of heavily contaminated or highly viscous samples. When used in-series preced-ing a membrane filter, clogging of the membrane filter is prevented and sample clean up is optimized. Outlet connection is luer lock. AF0-8515-12 7 100/pk AF0-8515-52 7 500/pk Phenex Syringe Filters Ordering Information 1 Above syringe filters are non
Membrane Filter Chemical Compatibility Chart - Support
1) Syringe filter housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices. 2) Solutions at temperatures up to 100°C can be filtered using syringe filters. 3) Syringe filters can be sterilized by autoclave at 125°C for 15 minutes.
Titan3™ PTFE (Hydrophobic) Syringe Filters
Available in sizes and membrane types to meet any application need, Thermo Scientific™ Titan3™ PTFE Hydrophobic Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles. These filters are used for filtration of aggressive organic, highly basic or hot solutions and as transducer protectors.
PTFE Membrane Filter-Hydrophobic | Simsii,Inc.
PTFE membrane filter from Simsii is the ideal choice. Our range of PTFE filters is designed with strong inherent properties and smooth surfaces. These filters are resistant to strong acids, solvents, and bases.
Performance and Protection - Phenomenex
syringe filter membrane performance. Generally, 0.45 µm porosity filters are used to remove particulates from samples and mobile phase solutions. For sterile-filtration, a 0.20 µm porosity filter can be used. Application / Sample* Recommended Filter First Alternative HPLC and GC Sample Prep RC PTFE Aggressive or Pure Organic Solvents PTFE RC
Difference between hydrophilic and hydrophobic filters
Hydrophobic filters are best suited for gas filtration, low surface tension solvents, and venting. In certain applications, hydrophobic filters are used to filter aqueous solutions because of compatibility requirements. Water or aqueous solutions can also pass through a hydrophobic filter once the water breakthrough pressure is reached.
Phenomenex Catalog International 2009 - Nxtbook Media
Filtration Syringe Filters (cont’d) Syringe Filter Applications and Recommended Membranes Application / Sample HPLC and GC Sample Prep Aggressive or Pure Organic Solvents Protein Analysis / Biological Samples High Particulate Loads Environmental Methods Food and Beverage Clinical / Toxicology Dissolution Testing Ion Chromatography Trace Metals (ICP-MS, AAS) Capillary Electrophoresis (CE
Glass Solvent Filter – Membrane Solutions
Membrane Solutions (1-800-553-9057) is rather professional in Membrane filter manufacture and sales. Solvent filtration is used primarily in microbiological and analytical procedures that involve collecting a particulate (bacteria, precipitate, etc.) from a liquid suspension.
PTFE Membrane Filters - Membrane Filters | Sigma-Aldrich
Milliseal Membrane Seal, PTFE, 18 mm This is a 18 mm Hydrophobic PTFE Membrane Filter with a 0.45 micron pore size. For use in Sterilizing filtration, bioassays, solvent filtration. pricing
Membrane filter, PTFE Hydrophobic - ProSciTech
The PTFE membrane is made of pure PTFE, laminated to a polypropylene support for improved durability. This membrane is simply the best choice for use with aggressive solvents, liquids, and gases that may attack other media. It is resistant to most acids, alkalis, and solvents. Laminated PTFE filters can also be used to
Minisart® SRP15 Syringe Filter 17574----------Q, 0.45 µm
Minisart® SRP15 Syringe Filter 17574-----Q, 0.45 µm hydrophobic PTFE Minisart ® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17574 with a pore size of 0.45 µm can be used for sample preparation.
GEnERAL LABORATORY COnSUMABLES - Phenomenex
Widely used for (PTFE, Teflon®) chromatography, and for clarification of non-aqueous samples. Although this membrane is hydrophobic, it can be made hydrophilic by wetting the membrane with alcohol and then flushing with deionized water. Phenex™ SYRINGE FILTERS For HPLC and GC sample and solvent filtration
HPLC ACCESSORIES - Phenomenex
Recommended filter membranes: Nylon 66® is a highly resistant material and can be used with almost all laboratory solvents. Since Nylon 66 is hydrophilic, no prewetting of the filter is required. PTFE (Teflon®)membrane filters are excellent for organic or other aggressive solvent systems. Extremely low levels of extractables
Hydrophobic membrane filter Manufacturers & Suppliers, China
hydrophobic membrane filter manufacturer/supplier, China hydrophobic membrane filter manufacturer & factory list, find qualified Chinese hydrophobic membrane filter manufacturers, suppliers, factories, exporters & wholesalers quickly on Made-in-China.com.
Syringe Filter Selection for HPLC or LC/MS samples
Nov 15, 2014 · Polytetrafluoroethylene (PTFE): Reported in most brochures to be chemically resistant to almost all solvents, strong acids and bases. Hydrophobic membrane should be pre-wetted when used with aqueous solutions. Low protein binding and very strong. Can be autoclaved. Most chromatography grade syringe filters are constructed of either HDPE or PP.
UHPLC/HPLC Sample Filtration 2. characteristics of your
Can be used alone or in series with other Phenex filter membranes such as the 0.20 µm pore Phenex-RC filter to reduce clogging of the membrane and optimize flow. Phenex Syringe Filter Ordering Information 4 mm diameter for ≤ 2 ml sample volumes 15 mm diameter for 2 - 10 ml sample volumes 25 -28 mm diameter for 10 - 100 ml sample volumes membrane
Hydrophobic PTFE membrane for Liquid Filtration, PTFE
MS PTFE membrane media for filtration is made of PTFE(polytetrafluoroethylene), and were drawn 2-demension. It is micro-pore film. The PTFE membrane was laminated with s great variety of fabric and paper. They are new filter media.
World Pharmaceutical Technology ® • Products and devices for
Syringe Filter 13 0.45 Hydrophobic PTFE 100pcs/pack RSF16TS Syringe Filter 13 0.22 Hydrophobic PTFE 100pcs/pack RSF15TQ Syringe Filter 13 0.45 Hydrophilic PTFE 100pcs/pack RSF16TQ Syringe Filter 13 0.22 Hydrophilic PTFE 100pcs/pack RSF1701F Syringe Filter 25 0.1 Hydrophobic PTFE 100pcs/pack
Membrane Disc Filters | Foxx Life Sciences – shopfls
Foxx Life Sciences brings an advanced collection of Membrane Disc Filters available in gridded, glass fiber, hydrophobic PTFE, and nylon to match your specific requirements. All materials comply with USP Class VI Standards to guarantee the quality of your filtration especially for aggressive solutions like DMSO and alcohols.
Performance and Protection - Microsoft
syringe filter membrane performance. Generally, 0.45 µm porosity filters are used to remove particulates from samples and mobile phase solutions. For sterile-filtration, a 0.20 µm porosity filter can be used. Application / Sample* Recommended Filter First Alternative HPLC and GC Sample Prep RC PTFE Aggressive or Pure Organic Solvents PTFE RC
medical DIAFIL innovations FILTRATION DEVICES
PTFE is naturally very clean and inert for use even in highly aggressive solvents. • Due to its strong hydrophobic characteristics PTFE filter are used mainly for filtration of samples that contain organic solvents. • Compatible with both strong acidic and basic solutions. • Improved durability and handling GLOBAL HEADQUARTERS 1.800.669.1535
HPLC Mobile Phase Filtration Kit | Pall Shop
Membranes are identical in composition and quality to those used in Pall’s HPLC-certified Acrodisc ® syringe filters; HPLC certification assures that the filters will not add artifacts to your analysis; GH Polypro membrane is the best choice for filtering mobile phases; PTFE membrane provides the ultimate in chemical compatibility for
Hplc Solvent Filter at Thomas Scientific
membrane filters come in a variety of pore sizes and diameters. High chemical resistance and mechanical strength One of the major applications for the PTFE membrane is the clarification of corrosives, solvents, and aggressive fluids. This includes the important requirement in HPLC…