Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA) Qty/Pack: 100pcs/pack Application: Filter Payment: T/T MOQ: 1 pack
Inquiry Chat Now
Product Description

Rc Syringe Filter at Thomas Scientific

® SRP syringe filters with a clean and chemically inert PTFE membrane. The units are ready-to-use and allow for simple, rapid and reliable ultracleaning of small volume samples for HPLC or GC analysis, which require an even more chemical resistant unit than Minisart ® RC, e.g. for solvents

Syringe Filters for HPLC & Sample Preparation | analytics

The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are used for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3

4 Mm Syringe Filter at Thomas Scientific

Minisart ® SRP syringe filters with a clean and chemically inert PTFE membrane. The units are ready-to-use and allow for simple, rapid and reliable ultracleaning of small volume samples for HPLC or GC analysis, which require an even more chemical resistant unit than Minisart ® RC, e.g. for

Syringe filters, Minisart® SRP | VWR

Syringe filters, Minisart® SRP. Minisart® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. For hydrophilic solutions pre-rinsing with a solvent is necessary to make the hydrophobic membrane permeable for aqueous liquids.

Minisart filters pore size 0.2 μm | Sigma-Aldrich

Minisart filters have a Luer Lock inlet and outlet, for positive attachment to the syringe. The filter is 26 mm in diameter with a hold-up volume of 0.1 mL. Suitable for clear aqueous solutions not requiring preliminary filtration.

How to Choose Right Syringe Filter -- Filter Membrane Materials

Jan 08, 2017 · PTFE membranes are chemically resistant to nearly all solvents, acids and bases. The membrane has low extractable and good thermal stability. PTFE is hydrophobic and requires pre-wetting prior to use with aqueous solvents. Sterilization: Syringe filters can be sterilized by autoclave at 125° for 15 minutes.

Minisart Syringe Filters The Easy Choice – Clean and Safe

biggest amongst premium syringe filters and the MBS housing is color-coded for easy pore size identification. See page 10. Medical Use and Sterile Venting Special Applications Minisart® syringe filters are ideal for clarification of liquids laden with particles, e.g. for preparation of pharmaceuticals or infusion solutions.

Understanding syringe filters – Andy Connelly

Sep 28, 2016 · First published at see.leeds.ac.uk on 30th October 2015. Updated 10th November 2017 by Andy Connelly. Introduction. Syringe filters are generally used to remove particles from a liquid sample prior to some kind of analysis to avoid damage to equipment (e.g. ion chromatography, ICP, etc.)

SartoriusMinisart RC Syringe Filters:Filters and Filtration

Sartorius Minisart™ RC Syringe Filters utilize a regenerated cellulose membrane for clarification of small volume samples. Choose from 0.2 and 0.45μm pore sizes in 15, 25 and 4mm diameter filters. Simple, rapid and reliable filtration. Contains a hydrophilic, solvent-resistant regenerated cellulose (RC) membrane.

How to Select a Syringe Filter and How to Use it? (2020 Guide)

Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).

16553----------K - Syringe Filter, Minisart High Flow, PES

The Minisart High Flow is a syringe filter for rapid volume sterilisation with maximum user convinience. Ready-to-use units, which offer flow rates at low inlet pressures, allow for a correspondingly rapid sterile filtration.

Sartorius Minisart™ SRP Syringe Filters - Fisher Sci

Designed for ultracleaning of small volume samples for the HPLC or GC analysis. Sartorius Minisart™ SRP Syringe Filters are single-use filtration units with a chemically resistant PTFE membrane and male luer slip outlet. Available in 4, 15 and 25mm diameter filters with 0.2 or 0.45 μm pores. Simple, rapid and reliable ultracleaning.

Syringe and Syringeless Filters | Fisher Scientific

Syringe and Syringeless Filters; Syringe and Syringeless Filters 1 – 30 1132 . Interest Areas. Life Science; Chemicals; Chromatography; Industries; Fisherbrand

Sterile Syringe and Syringeless Filters - Fisher Sci

Syringe and Syringeless Filters; Sterile Syringe and Syringeless Filters; Sterile Syringe and Syringeless Filters 1 – 30 1132 . Industries. Government

Sartorius Minisart™ SRP Syringe Filters: Syringe and

Designed for ultracleaning of small volume samples for the HPLC or GC analysis. Sartorius Minisart™ SRP Syringe Filters are single-use filtration units with a chemically resistant PTFE membrane and male luer slip outlet. Available in 4, 15 and 25mm diameter filters with 0.2 or 0.45 μm pores.