HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters
HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters

Free sample hplc filter ptfe membrane filter for hplc thermo fisher

Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA) Qty/Pack: 100pcs/pack Application: Filter Payment: T/T MOQ: 1 pack
Inquiry Chat Now
Product Description

Laboratory Filters | Filtration Products | Waters

HPLC sample filters in syringe filter format; Solvent filters in membrane disc format; Solvent filtration apparatus; A wide selection of membrane types and pore sizes to deliver the right lab filter for any sample type, and a broad range of device sizes to ensure complete sample filtration with minimal sample loss.

Syringe Filters - Fisher Sci

Bottle Tops and Filter Units; Extraction Thimbles; Filter Holders and Hardware; Filter Paper; Filtering Funnels; Food and Beverage Testing; Glass Fiber Filters and Prefilters; Membranes for Filtration; Syringe and Syringeless Filters; Water Testing and Environmental Analysis

Syringe Filters for HPLC and sample preparation | analytics

Pore Sizes and Pore Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are usually for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm

Thermo Scientific™ Nalgene™ Syringe Filters - Fisher Sci

Filter sample volumes of 10 to 100mL with these nonsterile syringe filters featuring a variety of membranes and pore sizes for most laboratory applications. Brand: Thermo Scientific™ 725-2520

Titan3 and Target2 Chromatography Syringe Filters

PTFE Biological load sample preparation Cellulose Acetate (RC) Protein and peptide samples, general HPLC Polypropylene (PP) Highly particulated samples Glass MicroFiber (GMF) Sample volume Membrane compatibility with sample type and technique Size and amount of particulates in the sample > 100 mL 30 mm 0.22 µm 0.45 µm GMF > 10 mL 17 mm > 2 mL

Centrifugal Filter Devices - Fisher Sci

Bottle Tops and Filter Units; Extraction Thimbles; Filter Holders and Hardware; Filter Paper; Filtering Funnels; Food and Beverage Testing; Glass Fiber Filters and Prefilters; Membranes for Filtration; Syringe and Syringeless Filters; Water Testing and Environmental Analysis

Polypropylene (PP) membrane, PP membrane – Membrane Solutions

Depth Filter PP Pleated cartridge filters PolyPure®Classic PolyPure®AB High Flow cartridge filters 600 FlowPure®-HF Melt Blown Filters MicroPure®Classic String Wound Filters AqurePure Classic KleenPure®Swimming and Spa Filter Membrane Filter PTFE membrane cartridge filter FluorPure® FluorPure®-EV AFS-Pure® PFA PES membrane cartridge

Syringe and Syringeless Filters - Fisher Sci

Fisher Scientific SAS - Boulevard Sébastien Brant - F67403 Illkirch Cedex - France Tél. 03 88 67 14 14 - Fax. 03 88 67 11 68 - fr.fisher@thermofisher.com S.A.S. au capital de EUR 104.044.489, SIRET 398 827 337 00021 RCS Strasbourg, N° TVA : FR 21 398 827 337

FisherbrandSyringe Filters: PTFE Membrane:Filters and

Tested for 100% membrane and housing integrity, eliminating concerns about fluid loss. PTFE Membrane. Hydrophobic PTFE membrane has great temperature resistance; Ideal for degassing/clarifying aqueous and solvent samples; This product(s) resides on a Fisher Scientific GSA or VA contract.

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Sample filtration is a fast and cost effective way of removing particulates from your sample. Wide variety of membrane material available. (Cellulose, Glass microfiber, nylon, PES, PTFE, PVDF.) Chemical compatibility between the filter membrane and your sample is key! • Solvent resistance • Binding of analyte to membrane

Thermo Scientific Choice Syringe Filters

Hydrophilic PTFE filters do not require pre-wetting for use with aqueous samples. Hydrophobic PTFE filters require pre-wetting with an alcohol before use with aqueous samples. Specifications Membrane: HPLC certified PTFE, w/polypropylene support Maximum operating temperature: 110 °C Housing: Medical grade, virgin polypropylene

Fisherbrand™ Non-sterile PTFE Syringe Filter: Syringe and

Designed for daily routine analysis. Fisherbrand™ Non-sterile PTFE Syringe Filter features a hydrophobic PTFE membrane for filtering HPLC organic solutions. Available in two membrane diameters (13 and 25mm) and two (0.2 and 0.45µm) pore sizes.

Choice™ PTFE (Hydrophilic) Syringe Filters

Use Thermo Scientific Choice PTFE Hydrophilic Syringe Filters for filtration of aggressive organic, highly basic or hot solutions, and as transducer protectors. These Choice Syringe Filters can filter aqueous solutions without the need for pre-wetting with an alcohol. They provide cleaner sample ext

Syringe Filters - Fisher Scientific

Fisher Scientific - Guldensporenpark 26 - 9820 Merelbeke - Belgium Tel. 056 260 260 - Fax. 056 260 270 - be.fisher@thermofisher.com S.R.L. au capital de EUR 18 550, RCS Bruxelles 667572, N° TVA : BE 47 92 91 549

HPLC & Chromatography Vials - Membrane filters, syringe

Chromatography vials are containers designed to temporarily hold samples analyzed as a part of gas (GC) or liquid (HPLC) chromatography. Tisch Scientific offers an extensive selection of vials that have passed the ISO9001:2015 quality certification making them the highest quality in the industry to ensure the most accurate analysis of your samples.

Inquiry
Send on email.all fields width on * are required. Please enter your question and contact information.we will get back to you as soon as possible!