Free sample wheel filters ptfe filters for hplc vwr
Nalgene Syringe Filters - Thermo Fisher Scientific
filters are designed for clarification and particle removal from samples for instrument analysis such as HPLC and GC. Sample Preparation for Chromatography Pore size (µm) Membrane Housing Catalog # #/Case 13mm diameter for 2-10 ml volume, Leur-Lok inlet, male slip outlet 0.2 PTFE Polypropylene 721-1320* 100 0.45 PTFE Polypropylene 721-1345* 100
Filtration, Filters, Syringes, and Hypodermic Needles
Syringe filters with high burst strength for assured performance. Manufactured to ISO 9002 and GMP standard and 100% integrity tested. Syringe filter sizes include 4, 15, 25, or 26mm diameter to handle volumes ranging from 0.5 to 100 ml. The 50mm diameter "PTFE" syringe filter are ideal for protecting the vacuum line and pump.
Venting Filters | VWR
Description: These safety exhaust filters can be placed on the waste bottle of an HPLC system, to protect workers from solvent vapors in the ambient air. ,JOURJR-S-20005EA,JOURJR-S-20002EA Microfilters, MS-681, Munktell
ZapCap® bottle-top filters ZapCap-CR, PTFE membrane, pore
ZapCap-CR Filtration of HPLC solutions: 1. Polyamide membrane filters (NYL) for filtering down to 0.2 μm in HPLC/FPLC solutions when the column packing is 10 μm 2. PTFE membrane filters for filtering down to 0.45μm in organic solutions; strong acids or aldehydes ZapCap-S Filtration of cell culture media: 1.
Sartorius Syringe Filters 17574-Q | Lab Unlimited
Syringe filter Minisart SRP, PTFE With a chemical-resistant, hydrophobic PTFE membrane for high purification of solvents or aggressive liquids in HPLC or GC analysis. Low adsorption. With female luer-lock inlet, male luer slip outlet. Non-sterile. Product Specification: Filter diam.: 15mm Pore size: 0.45 µm Housing: PP Type: non sterile
Syringe Filters | Sigma-Aldrich
Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
dk.vwr.com Innovative products for Chromatography
Acrodisc® PSF syringe filters with PTFE, 25 mm, 0,2 mm 1000 514-0478P 16.820,00 13.456,00 Acrodisc® PSF syringe filters with PTFE, 25 mm, 0,45 mm 1000 514-4232P 16.820,00 13.456,00 Acrodisc® PSF GxF syringe filters with PTFE, 25 mm, 0,45 mm 1000 514-4230P 16.820,00 13.456,00
PTFE Hydrophilic Membrane Filters, Advantec MFS | VWR
PTFE Hydrophilic Membrane Filters, Advantec MFS. Filters Membrane Filters. Advantec Hydrophilic PTFE membrane filters are ideal for HPLC and other mixtures of aqueous and organic solvents. This non-supported membrane is very thin and optically clear when wet. Thermostable up to 100°C.
Syringe Filters: Amazon.com
Syringe Filters PTFE Membrane - Hydrophilic Filtration,0.22um Pore Size, 25mm Membrane Diameter (PTFE 25mm 0.22μm 15pcs) 4.5 out of 5 stars 32 Nylon Syringe Filters [Wettability: Hydrophilic Nylon Membrane] 25mm Diameter 5.0 μm Pore Size Laboratory Filters by Allpure Biotechnology (Pack of 100) (Nylon, 5.0 μm)
Syringe filters | VWR
Available with either PP, PTFE or nylon membrane. Membranes are available in either 0,2 or 0,45 µm pore size, with the choice often made on analytical column packing size. If the column packing size is larger than 3 μm then use 0,45 μm, and if 3 μm or smaller then use 0,2 μm.
Syringeless Filters | VWR
Available in a variety of filter media, syringeless filters allow you to process sample loads in a fraction of the time, providing a quick, economical, and environmentally conservative way to filter samples prior to HPLC analysis. These are preassembled filtration devices specially used in HPLC for the purification and analysis of samples.
Millex Syringe Filter Unit, Hydrophilic PTFE, Non-sterile
Millex Syringe Filter Unit, Hydrophilic PTFE, Non-sterile Replaces SLLGH13NL, 0.20 µm pore size, 13 mm diameter, Millex-LG hydrophilic PTFE membrane - Find MSDS or SDS, a COA, data sheets and more information.
Analytical Sample Prep | VWR
With high-quality filters for sample preparation and dissolution testing, Pall is able to meet the unique requirements of every lab with a wide variety of membranes including the new wwPTFE membrane “the next generation in universal membrane filtration” as well as Nylon, PVDF, hydrophobic PTFE membranes, and more.
Filtre | VWR
Beskrivelse: These vacuum filter units are very useful in large volume samples separation and purification. Tilbud ,514-1035EA,514-1066EA,514-1046EA,514-1021EA,514-1022EA,514-1063EA,514-1012EA
Syringe filters, analytical filtration, Nalgene® | VWR
PTFE membrane; PP housing: Naturally hydrophobic for sterile venting applications and filtration of samples in HPLC/GC solvents. Ideal for sterile venting of air or other gases during filtration. Ideal for sterile venting of air or other gases during filtration.