HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters
HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters

Professional hplc filter ptfe membrane filter for hplc millipore

Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA) Qty/Pack: 100pcs/pack Application: Filter Payment: T/T MOQ: 1 pack
Inquiry Chat Now
Product Description

Quick Reference Guide Millex Syringe Filters

Choose From a Variety of Membranes • Millex-LCR filter contains a Millipore-exclusive hydrophilic PTFE membrane and are HPLC-certified for low levels of UV-absorbing extractables. They provide the cleanest sample for HPLC analysis. • Durapore® (PVDF) filters combine fast flow with low protein binding.

Pvdf Membrane Filter Millipore - Autosampler Vial, Hplc Vial

* PVDF Membrane Filter Millipore can be customized in diameter and pore size based on big quantity; * Factory can supplying rich filter material, such as Nylon, PTFE, PVDF, PES, CA, MCE * Factory do regular stocking for PVDF Membrane Filter Millipore. * One of leading manufacturers in filtration consumables field. 2. Related Services

EMD Millipore SLLHR04NL HPLC Certified Syringe Filter, LCR

Buy EMD Millipore SLLHR04NL HPLC Certified Syringe Filter, LCR PTFE, 0.45um, 4mm dia, 100/pk and more from our comprehensive selection of Millipore Syringe Filters

Millipore FHLC01300 White PTFE LCR Hydrophilic Membrane

LCR is an unsupported hydrophilic PTFE membrane compatible with all commonly used HPLC solvents. It can be used to filter aqueous fluids without prior wetting. Available in syringe filters. Filter Material: Hydrophobic PTFE. Media Brand Name: Hydrophilic LCR (PTFE). Filter type: Screen filter. Pore Size ( m): 0.45. Wettability: Hydrophilic.

Fluoropore Membrane Filter | FHUP04700 - Merck Millipore

Our Omnipore™ membrane is a hydrophilic PTFE membrane that is compatible with virually all solvents, acids, and alkaline solutions. Features & Benefits: - Biologically and chemically inert - High porosity yields high flow rates - Hydrophobic and hydrophilic PTFE varieties available for filtration of aqueous and organic-based samples Applications:

Syringe Filters | Life Science Research - Merck Millipore

Syringe filters: How Quality Could Make or Break Your HPLC This short animation explains how your syringe filter might be putting your HPLC at risk. Some syringe filters exhibit unpredictable loss of membrane integrity, allowing particles to pass through the filter. These particles could contaminate and/or clog the expensive HPLC column.

Membrane Filter Chemical Compatibility Chart - Support

1) Syringe filter housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices. 2) Solutions at temperatures up to 100°C can be filtered using syringe filters. 3) Syringe filters can be sterilized by autoclave at 125°C for 15 minutes.

Millipore Filters 0.45 Um - Autosampler Vial, Hplc Vial, PTFE

Home > Products > Welded Syringe Filter > PTFE Syringe Filter Millipore Filters 0.45 Um Economy syringe filter is very popular in whole market, especially big package, as it can save more cost for customers.

Membrane Filters for Lab Filtration | analytics-shop.com

PTFE membranes are extremely resistant to aggressive solvents and acids and can be used to filter particulate from both liquid and gas samples. Regenerated Cellulose (RC) Regenerated cellulose membranes are resistant to solvents and are hydrophilic. 0.45 μm pore size is typically used for HPLC sample preparation.

HPLC Filter Degasser | Safety Products | MilliporeSigma

Filters Harmful Particulates. An internal 0.2mm PTFE membrane filters out harmful particulates which can cause damage to expensive pumps and detectors. Easy-to-Use. Filters and degasses 4L of solvent in 10 minutes without operator attention. Durable PTFE Construction. Strengthened PTFE construction of unit enhances degasser's longevity.

MilliporeSigmaFluoropore PTFE Membrane Filters:Filters and

Made from polytetrafluoroethylene (PTFE) bonded to high-density polyethylene Wetting with methanol or another low-surface-tension fluid renders the membrane hydrophilic Mean thickness varies from 145 to 200μm, depending upon filter type Provides broad chemical compatibility

LCR Membrane Filter | FHLC04700 - Merck Millipore

LCR Membrane Filter: Background Information: LCR membrane is an unsupported, hydrophilic PTFE membrane compatible with all commonly used HPLC solvents. The membrane undergoes a special treatment process to remove any residual extractabes, ensuring that it will not add anything to your HPLC solvents, providing clearer analysis results.

The Membrane Selector Guide - Fisher Sci

Key Applications HPLC mobile phase filtration, clarifying acids, bases and dilute protein solutions Devices Millex® syringe filters, Millex Samplicity® filters, filter discs Nylon Membrane Membrane Material Nylon Pore Sizes (µm) 0.2 - 1.2 Thickness (µm) 150 - 190 Water Flow Rate (mL/min/cm2)@ 27.5 in. Hg 8.0 - 21.2 (typical value)

MilliporeSigma FHLC04700 LCR PTFE Membrane Filter

The Millipore LCR filter is an unsupported hydrophilic PTFE membrane filter compatible with all commonly used HPLC solvents. These PTFE membrane filters are ideal for filtering aqueous fluids without prior wetting. Wetting time required for other liquid filtrants is less than five seconds. PTFE membrane construction is chemically inert and may be used with most all lab reagent chemicals

Mobile Phase Filtration - Laboratory | Pall Corporation

We offer several filters to accommodate the various types of HPLC solvents. Our wwPTFE (water wettable polytetrafluoroethylene) membrane is a universal solvent membrane to reduce confusion with filter selection. Typical membrane filters range in size from 25 to 90 mm in diameter and are available in a 0.2 or 0.45 μm membrane pore size.

Mobile Phase Filtration - Laboratory | Pall Corporation

We offer several filters to accommodate the various types of HPLC solvents. Our wwPTFE (water wettable polytetrafluoroethylene) membrane is a universal solvent membrane to reduce confusion with filter selection. Typical membrane filters range in size from 25 to 90 mm in diameter and are available in a 0.2 or 0.45 μm membrane pore size.

Customised Mce,Ptfe,Pvdf,Pes Nylon Syringe Filter,Sterile

Customised MCE,PTFE, PVDF,PES Nylon Syringe Filter . Instruction: Syringe filters are a cost-effective way to improve the quality of HPLC analysis, improve consistency, extend column life and reduce maintenance. By removing particulates before the sample enters the column, syringe filters allow unimpeded flow.

Mitex™ PTFE Membrane Filters - Filter Discs and Membranes

Reagents, Chemicals and Labware > Lab Filtration > Filter Discs and Membranes C135891Pure PTFE Mitex™ PTFE Membrane is unaffected by almost all liquids, including organic solvents, concentrated acids and bases, propellants, and cryogenic fluids.

Millicup-FH, 0.45 µm, hydrophobic, PTFE, non-sterile Non

The Millicup Filter Unit provides fast and effective filtration of solvents and buffers (up to 3L) used in HPLC and other analytical techniques. Features & Benefits: •No preparation or clean-up saves time •Available with low-protein binding hydrophilic Durapore PVDF, hydrophobic Fluoropore PTFE, and hydrophilic LCR PTFE membranes

Corning Filtration Guide

Clarification of Aqueous Solutions 0.45 All membranes except PTFE Clarification of Solvents (HPLC) 0.45 RC, nylon, and PTFE Coarse Particle Removal 0.8 SFCA, glass fiber prefilters PES = polyethersulfone, PTFE = polytetrafluorethylene; RC = regenerated cellulose; SFCA = surfactant-free cellulose acetate. Step 2: Select the membrane and housing

Whatman Lab Filtration Products – Analytical sample

Whatman provides a wide range of syringe filters, accessories, integrated devices and inline filter-degassers to address laboratory filtration needs from basic to the most demanding, for small research facilities to high-throughput analytic labs.

Filtration Media Selection Guide - Membrane filters, syringe

PP membranes are a good choice for filtration of HPLC samples when performing protein analysis by chromatography. In addition to being highly solvent resistant, these membranes are low non-specific adsorbing membranes, which results in maximum protein recovery for critical analysis.

MilliporeSigmaMillex Samplicity Filters, Hydrophilic PTFE

MilliporeSigma™ Millex Samplicity™ Filters, Hydrophilic PTFE To be used with the Samplicity Filtration System. Powered by vacuum, the system takes minimal manual effort to filter 1 to 8 samples into standard HPLC vials in seconds, with higher recovery than syringe filters provide.

LCR Membrane Filter | FHLC02500 - EMD Millipore

LCR membrane is an unsupported, hydrophilic PTFE membrane compatible with all commonly used HPLC solvents. The membrane undergoes a special treatment process to remove any residual extractabes, ensuring that it will not add anything to your HPLC solvents, providing clearer analysis results.

PTFE Membrane Filters, 0.22 Micron Hydrophobic Membrane

PTFE filter is a kind of membrane material for deep filtration. Membrane filter disc has the following characteristics: membrane filter 0.22 μm is produced from food-grade isotactic polypropylene. No additives in the whole process; stable physical and chemical properties and good compatibility.

0.45 Filter at Thomas Scientific

Minisart ® SRP syringe filters with a clean and chemically inert PTFE membrane. The units are ready-to-use and allow for simple, rapid and reliable ultracleaning of small volume samples for HPLC or GC analysis, which require an even more chemical resistant unit than Minisart ® RC, e.g. for

PTFE Membrane Disc Filters - Mobile Phase Filtration

PTFE Membrane Disc Filters HPLC Mobile Phase Filtration Membranes - 0.2 µm, TF (PTFE) membrane (100/pkg) Product ID 66143. Diameter 47 mm. Filter Media PTFE.

Nalgene™ Syringe Filters - Thermo Fisher Scientific - US

Thermo Scientific Nalgene syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications.

Microfiltration Membranes - EMD Millipore

A key sample preparation technique, microfiltration removes micron-range particles or biological entities from fluids by passage through a microporous medium, such as a membrane filter. MilliporeSigma, with over 50 years of filtration expertise, sets the industry standard for high-performance membrane technology for sample preparation.

Solvent Compatibility Chart for Syringe Filters

Syringe Filters Solvent Compatibility Chart 1 Protect any analytical system. 2 Extend LC column lifetime. 3 Achieve more reproducible analyses. 4 Variety of membranes, porosities, and diameters available. 5 Luer lock inlet provides strong, leak-tight syringe connection to withstand filtration pressure.

Inquiry
Send on email.all fields width on * are required. Please enter your question and contact information.we will get back to you as soon as possible!