Professional hydrophilic ptfe filters for hplc minisart
Syringe Filters - Fisher Sci
Fisher Scientific Italia, Strada Rivoltana Km 4, 20053 Rodano (MI), Italy Tel. 02 950 59 478 - Fax. 02 950 59 479 - it.fisher@thermofisher.com
The Advantages of Minisart Hydrophilic Syringe Filters for
Filtered using hydrophilic PTFE, competitor A Filtered using PVDF, competitor A Filtered using Minisart ® NY Filtered using Minisart ® RC Unfiltered Acetonitrile materials below). Our regenerated cellulose (RC) membrane used in Minisart ® RC and our polyamide (= nylon) membrane incor-porated in Minisart ® NY are exceptionally pure compared with other common hydro-philic filter membranes and competitor products.
Corning Filtration Guide
The HPLC-certified non-sterile syringe filters are available with nylon, regenerated cellulose or polytetrafluorethylene (PTFE) membranes in polypropylene housing for extra chemical resistance.
Non-Sterile Syringe and Syringeless Filters | Fisher Scientific
Non-Sterile Syringe and Syringeless Filters; Non-Sterile Syringe and Syringeless Filters 1 – 30 1132 . Interest Areas. Life Science
HPLC Mobile Phase Filtration Membranes
PTFE membrane provides the ultimate in chemical compatibility for filtering harsh chemicals and HPLC mobile phases Application Purification and degassing of mobile phase solvents used in liquid chromatography applications Specifications Filter Media GH Polypro (GHP, hydrophilic polypropylene), TF (PTFE, hydrophobic polytetrafluoroethylene), PVDF
.45 Ptfe Syringe Filter at Thomas Scientific
mdi Hydrophilic PTFE membrane Syringe filters are color coded for ease of identification and offer a number of unique performance advantages: HPLC Certified for low levels of UV-absorbing extractables Hydrophilic, no pre-wetting required Unique 16-channel design for very low hand
Minisart Syringe Filters for HPLC Sample Preparation
Available in a Choice of Membranes: Hydrophilic Regenerated Cellulose (RC), Nylon (PA) or Hydrophobic PTFE Sartorius Minisart ® filters reliably remove particles from your samples without adding unwanted extractables or leachables. The purpose of using syringe filters for sample preparation prior to analysis is to protect analytical equipment and columns. Acetonitrile HPLC Procedure Column C18: 250 × 4.6 mm, Flow Rate: 1 ml/min, Wavelength: 210 nm
Syringe Filters for Aqueous Solutions - Support
Hydrophilic PTFE (Polytetrafluoroethylene) – strong membrane can handle high temperature liquids, excellent flow rates, low protein binding, high loading capacities, compatible with most bases, acids and solvents, PTFE ideal for aqueous, organic, or gaseous samples, PTFE multilayer filter ideal for aqueous and organic samples, cannot be used
Minisart Syringe Filters The Easy Choice – Clean and Safe
Minisart® Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases Sartorius offers Minisart ® syringe filters for a wide range of applications. The filters are clean and safe as they are almost free of leachables and exractables. Additionally, they reliably remove particles and microorganisms with no leakage.
Minisart® SRP15 Syringe Filter, 0.2 µm hydrophobic PTFE, 15mm
Minisart® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17573 with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
Syringe Filters | Fisher Scientific
Syringe Filters Merck Millipore Millex™-GP Sterile Syringe Filters with PES Membrane Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Main Applications Of Hydrophobic And Hydrophilic PTFE
Hydrophilic PTFE membrane filter is mainly used in: 1. Clarifies filtered acid, alkali, and cryogenic liquids and diluted protein solutions 2. Analysis of water samples to isolate RNA 3. Filtration of mixtures suitable for HPLC mobile phase and other water systems and organic solvents. Diameter is available: 13/25/47/50/60/90/110/142/150/200/250 mm.
Hydrophilic PTFE - Syringe Filters - Products
Kinesis is a leading international supplier of chromatography, liquid handling, sample storage and medicinal chemistry consumables and equipment. The ability to work directly with leading manufacturers enables us to offer very competitive pricing while ensuring that you, the customer, never have to compromise on quality, support or service.
Filters Minisart® Syringe 0.45um 15mm N/S PTFE pk 500
For hydrophilic solutions pre-rinsing with a solvent is necessary to make the hydrophobic membrane permeable for aqueous liquids. Due to the hydrophobic nature Minisart SRP can also be used for venting. The housing of the filter is made of PP (polypropylene) which is compatibility with harsh solvents, acids and bases.
Millex Syringe Filter Unit, Hydrophilic PTFE, Non-sterile
Millex Syringe Filter Unit, Hydrophilic PTFE, Non-sterile Replaces SLLGH13NL, 0.20 µm pore size, 13 mm diameter, Millex-LG hydrophilic PTFE membrane - Find MSDS or SDS, a COA, data sheets and more information.