Professional hydrophobic ptfe filters for hplc whatman
Whatman Syringe Filters | Disposable Syringe Filters
SOM CODE : D295/26 MODEL : 28195-868 COMPANY : VWR U.S.A SYRINGE FILTER WHITE 0.20U 50/PK IN PK For use with aggressive chemicals, including acids and nonaqueous solvents such as those used in GC, HPLC, or chemical etching. Filter media is hydrophobic PTFE with a natural polypropylene housing. Diameter: 25mm.
Whatman ReZist In-Line disk filters | Cytiva
Whatman ReZist in-line disk filters from Cytiva are lightweight devices suitable for venting, in-line filtration, and isolation applications when working with chemically harsh solvents. Integral hydrophobic PTFE venting membrane is resistant to harsh solvents
Whatman PTFE Membrane, TE Range, Whatman products (Cytiva) | VWR
Whatman PTFE membrane filters from Cytiva business are chemically stable and inert, making them suitable for use with aggressive organic solvents, strong acids, and alkalis.Membrane filters serve as effective physical barriers that remove solids, viruses, bacteria, and other unwanted molecules. Specialized types are designed for softening, disinfecting, organic removal processing, and water
Whatman® PTFE membrane filters PTFE - whatman filter
Whatman ® PTFE Membranes Whatman PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids, and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. The hydrophobic nature of the membrane also has applications for air and gas
Cytiva Whatman™ Puradisc 25mm PTFE Syringe Filters: Syringe
Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples. For filtering solvents, chemicals and nonaqueous solutions; Typical applications include HPLC, TLC, and GC sample clarification; HPLC solvent filtration; Made of hydrophobic polytetrafluoroethylene (PTFE)
Cytiva (Formerly GE Healthcare Life Sciences) Whatman
Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ Puradisc 25mm PTFE Syringe Filters Contains hydrophobic membrane that is chemically stable and inert. Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples.
CytivaWhatman PTFE Membrane Circles:Filters and Filtration
Provides clarification of corrosives, solvents, and aggressive fluids. Whatman™ PTFE Membrane Circles are particularly useful in HPLC analysis when solid particles can cause permanent damage to the column. Hydrophobic; Chemically stable and inert; Can be used up to 120°C; Laminated onto randomly arranged polypropylene support material
Syringe and Syringeless Filters - Fisher Sci
Syringe and Syringeless Filters; Syringe and Syringeless Filters 1 – 30 1132 . Interest Areas. Life Science
Hydrophilic Ptfe at Thomas Scientific
Hydrophilic PTFE syringe filters have broad chemical compatibility and high pH resistance and are optically clear when wet with water. They are versatile filters for use with aqueous and aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation.
Cytiva Whatman™ 30mm ReZist™ PTFE Syringe Filters
Whatman™ 30mm ReZist™ PTFE Syringe Filters are ideal for the clarification of aggressive organic solvents and can also be used as a venting filter for small vessels. Hydrophobic PTFE membrane is laminated with polypropylene; Optimal utilization of small sample volumes; Excellent chemical resistance against standard organic HPLC solvents
Hydrophilic Ptfe Membrane Filter at Thomas Scientific
Polytetrafluoroethylene (PTFE) - PTFE is inherently hydrophobic making this media ideal for air filtration and venting applications. Traps aqueous aerosols. Filter organic HPLC samples. PTFE-Hydrophilic - Filter aqueous solutions and organic solvents. This membrane is versatile and and
Whatman ® PTFE membrane filters - Sigma-Aldrich
Whatman ® PTFE membrane filters Whatman ® PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. See full list on sigmaaldrich.com
Whatman 7582-002, PTFE Membrane, WTP Range, 0.2 um pore size
Whatman PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids, and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. The hydrophobic ture of the membrane also has applications for air and gas sterilization.
Whatman PTFE Membrane Filters - Camlab
This includes the important requirement in HPLC analysis for sample filtration where any solid particles can cause permanent damage to the column. The 0.45µm pore size is normally used for HPLC applications. Air and gas sterilization make use of the hydrophobic characteristics of PTFE membrane filters and their ability to stop aqueous aerosols.
Whatman Ptfe Filteres at Thomas Scientific
Whatman PTFE membranes fromCytiva are strong hydrophobic membrane filters resistant to the corrosive solvents and aggressive media used in gas sterilization and liquid clarification. Polypropylene grid support material for increased strength Temperature resistant up to 120°C Resistant to most