HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters
HPLC Syringe Filters HPLC Syringe Filters HPLC Syringe Filters

Professional hydrophobic ptfe filters for hplc whatman

Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA) Qty/Pack: 100pcs/pack Application: Filter Payment: T/T MOQ: 1 pack
Inquiry Chat Now
Product Description

Whatman Syringe Filters | Disposable Syringe Filters

SOM CODE : D295/26 MODEL : 28195-868 COMPANY : VWR U.S.A SYRINGE FILTER WHITE 0.20U 50/PK IN PK For use with aggressive chemicals, including acids and nonaqueous solvents such as those used in GC, HPLC, or chemical etching. Filter media is hydrophobic PTFE with a natural polypropylene housing. Diameter: 25mm.

Whatman ReZist In-Line disk filters | Cytiva

Whatman ReZist in-line disk filters from Cytiva are lightweight devices suitable for venting, in-line filtration, and isolation applications when working with chemically harsh solvents. Integral hydrophobic PTFE venting membrane is resistant to harsh solvents

Whatman PTFE Membrane, TE Range, Whatman products (Cytiva) | VWR

Whatman PTFE membrane filters from Cytiva business are chemically stable and inert, making them suitable for use with aggressive organic solvents, strong acids, and alkalis.Membrane filters serve as effective physical barriers that remove solids, viruses, bacteria, and other unwanted molecules. Specialized types are designed for softening, disinfecting, organic removal processing, and water

Whatman® PTFE membrane filters PTFE - whatman filter

Whatman ® PTFE Membranes Whatman PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids, and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. The hydrophobic nature of the membrane also has applications for air and gas

Cytiva Whatman™ Puradisc 25mm PTFE Syringe Filters: Syringe

Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples. For filtering solvents, chemicals and nonaqueous solutions; Typical applications include HPLC, TLC, and GC sample clarification; HPLC solvent filtration; Made of hydrophobic polytetrafluoroethylene (PTFE)

Cytiva (Formerly GE Healthcare Life Sciences) Whatman

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ Puradisc 25mm PTFE Syringe Filters Contains hydrophobic membrane that is chemically stable and inert. Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples.

CytivaWhatman PTFE Membrane Circles:Filters and Filtration

Provides clarification of corrosives, solvents, and aggressive fluids. Whatman™ PTFE Membrane Circles are particularly useful in HPLC analysis when solid particles can cause permanent damage to the column. Hydrophobic; Chemically stable and inert; Can be used up to 120°C; Laminated onto randomly arranged polypropylene support material

Syringe and Syringeless Filters - Fisher Sci

Syringe and Syringeless Filters; Syringe and Syringeless Filters 1 – 30 1132 . Interest Areas. Life Science

Hydrophilic Ptfe at Thomas Scientific

Hydrophilic PTFE syringe filters have broad chemical compatibility and high pH resistance and are optically clear when wet with water. They are versatile filters for use with aqueous and aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation.

Cytiva Whatman™ 30mm ReZist™ PTFE Syringe Filters

Whatman™ 30mm ReZist™ PTFE Syringe Filters are ideal for the clarification of aggressive organic solvents and can also be used as a venting filter for small vessels. Hydrophobic PTFE membrane is laminated with polypropylene; Optimal utilization of small sample volumes; Excellent chemical resistance against standard organic HPLC solvents

Hydrophilic Ptfe Membrane Filter at Thomas Scientific

Polytetrafluoroethylene (PTFE) - PTFE is inherently hydrophobic making this media ideal for air filtration and venting applications. Traps aqueous aerosols. Filter organic HPLC samples. PTFE-Hydrophilic - Filter aqueous solutions and organic solvents. This membrane is versatile and and

Whatman ® PTFE membrane filters - Sigma-Aldrich

Whatman ® PTFE membrane filters Whatman ® PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. See full list on sigmaaldrich.com

Whatman 7582-002, PTFE Membrane, WTP Range, 0.2 um pore size

Whatman PTFE membranes are chemically stable and inert. They are suitable for applications involving aggressive organic solvents, strong acids, and alkalis. PTFE membranes are particularly suitable for preparing samples for HPLC analysis. The hydrophobic ture of the membrane also has applications for air and gas sterilization.

Whatman PTFE Membrane Filters - Camlab

This includes the important requirement in HPLC analysis for sample filtration where any solid particles can cause permanent damage to the column. The 0.45µm pore size is normally used for HPLC applications. Air and gas sterilization make use of the hydrophobic characteristics of PTFE membrane filters and their ability to stop aqueous aerosols.

Whatman Ptfe Filteres at Thomas Scientific

Whatman PTFE membranes fromCytiva are strong hydrophobic membrane filters resistant to the corrosive solvents and aggressive media used in gas sterilization and liquid clarification. Polypropylene grid support material for increased strength Temperature resistant up to 120°C Resistant to most

Inquiry
Send on email.all fields width on * are required. Please enter your question and contact information.we will get back to you as soon as possible!