vial sample for HPLC sampling on stock Aijiren
-
Aijiren Technologies Series HPLC Standard Operating
volume of the vial are simply placed inside the HPLC vial and loaded with sample. The cap is then screwed onto the vial as normal. Figure 1. An HPLC vial loaded with sample (right) and an optional 400 µL glass insert (left). • Place sample vials in the autosampler tray, making note of the position of each sample in the tray (you will need
Inquiry Chat Now -
Transferring an HPLC Method for Related Substances from
Separate stock solutions were prepared in methanol at 1.0 mg/mL. A metoclopramide stock solution was diluted with water to 0.5 mg/mL and spiked with related substances at 1.0% level. For a system suitability standard, each stock solution was transferred to one vial and diluted with standard diluent (50:50 methanol/water)
Inquiry Chat Now -
Aijiren 2 ml vials with caps in clear for HPLC sampling
2 ml vials with caps in amber for lab use supplier Amazon vials with caps in clear for HPLC sampling for sale VWR Amazon vials with caps in amber for Aijiren autosampler with high quality Aijiren Technologies Vial, Screw top, Amber with
Inquiry Chat Now -
Aijiren Thermostatted Autosampler | REUZEit
The Aijiren ALS Thermostat, controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to
Inquiry Chat Now -
CTC Analytics GC PAL Liquid Sampler | GenTech
Sample Capacity: 78 1 ml vials option; 98 2 ml vials standard; 32 10 ml or 20 ml vials option; Syringe sizes: 1.2 µl, 5 µl, 10 µl (standard), 25 µl, 100 µl, 250 µl, and 500 µl; Injection speed: Selectable from 0.01 µl/sec. up to 500 µl/sec. XYZ mechanism for fast sampling and/or rapid vial to vial transfers
Inquiry Chat Now -
amber 2ml screw cap glass vials with high quality Amazon
vials with caps in amber for HPLC supplier Aijiren-Aijiren . for , and autosamplers Screw top 4 mL glass vials are a custom fit to the Aijiren autosampler tray for use as sample as well as wash vials. Vials with fill marks are also appropriate for use as wash vials and waste vials in and
Inquiry Chat Now -
2ml autosampler vials with caps--Lab Vials Manufacturer
Our standard 2 mL vial is 12 mm in diameter, 32 mm in height, and has a 4.6 mm opening. 2ml hplc vials for autosampler on sale. The main application for HPLC, autosampler, chromatography, Aijiren, waters machine. All autosamplers of Ajiren Tech are 100% integrity tested and manufactured according to ISO 9001 standard.
Inquiry Chat Now -
G3280-67040 - Ni Sampling cone for 7700
G3280-67040 - Ni Sampling cone for 7700. Be the first to review this product. $623.00. SKU: G3280-67040. Overview. Specifications. ICP-MS sampler cone, Nickel, 1/pk. Suitable for single quadrupole 77/78/7900 and triple quadrupole 88/8900. Use with Nickel skimmer cone and stainless steel skimmer base. Standard cone used with x-lens.
Inquiry Chat Now -
Aijiren/Varian Straight Sealed Pyrex Sample Vials
SIS manufactures a number of standard size sample vials for Aijiren and Varian mass spectrometers. Vials are constructed of Borosilicate glass (Pyrex). O.D. tolerances are ±0.02 mm (0.001 inch) and length tolerance is ±0.20 mm (0.008 inch). The ends are cut clean and straight. Vials are clean and contamination free.
Inquiry Chat Now -
Sample Vials | VWR
Sample Vials. General-purpose sample vials are used for collection, storage, and transportation procedures. With a range of the material manufacturing and capacity options, users may tailor based on content and process requirements. Nonsterile or sterile vials are available in amber, white, or clear transparencies for effortless viewing.
Inquiry Chat Now -
Vials, Caps, and Vial Inserts | Aijiren
Aijiren vials and caps provide simple ways to boost laboratory productivity and return on investment. Aijiren premium certified vials, caps, high recovery vials, and vial inserts offer industry-leading performance; from the lowest bleed septum materials in our caps to the most inert glass vial materials, we are continuously refining our offerings by addressing small details delivering
Inquiry Chat Now -
Analytical methodologies for broad metabolite coverage of
Sep 01, 2017 · Chromatography was performed on an Aijiren HPLC system (Aijiren Technologies, Santa Clara, CA). Three replicate samples were analyzed using HILIC and three using RP chromatography. In between extraction and analysis, the samples were stored at −20 °C in capped LC vials with
Inquiry Chat Now -
Aijiren Series Injector with 100 Vial Autosampler
The Aijiren series automatic liquid sampler raises the standard for gas chromatography (GC) system performance and reliability. This next-generation Aijiren automatic liquid sampler for the Aijiren A, N, Plus and Series. This is the automatic sampler to have for: accuracy and ease of use; superior reproducibility, with
Inquiry Chat Now -
Vials, Caps, Inserts & Septa | Aijiren
Aijiren vials and caps provide simple ways to boost laboratory productivity and return on investment. Aijiren premium certified vials, closures, high recovery vials, and vial inserts offer industry-leading performance; from the lowest bleed septum materials in our caps to the most inert glass vial materials, we are continuously refining our offerings by addressing small details delivering
Inquiry Chat Now -
SYSTEM OPTIMIZATION MANUAL
Figure 2: Injector Program For Sample Focusing 1. The HPLC Method Focus your sample. Inject a volume of water, approximately 3x the sample injection volume, after the sample using an injector program. This will focus the sample on the head of the column and increase retention, resulting in narrower, more symmetrical peaks.
Inquiry Chat Now