Wholesales hydrophobic ptfe filters for hplc millipore
PTFE Syringe Filters - Non-Sterile Syringe Filters
PTFE Syringe Filters, 0.45 µm (250/pkg 750/cs)PTFE Syringe FiltersNon-Sterile Syringe Filters
Millex Syringe Filter, Fluoropore™ PTFE, Hydrophobic, Non
Description. Millex Syringe Filter, Fluoropore™ PTFE, Hydrophobic, Non-sterile. Background Information. Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions.
EMD Millipore SLFH013NL HPLC Syringe Filter, Fluoropore PTFE
Description HPLC Syringe Filter, Fluoropore PTFE, 0.45um, 13mm dia, 100/pk Key Features Fluoropore PTFE (polytetrafluoroethylene) is a hydrophobic PTFE membrane bonded to a high-density polyethylene support; ideal for clarification of organic solvents.
Non-Sterile Millex® Syringe Filter Selection Guide
Non-sterile IC Millex® Syringe Filters with LCR (Hydrophilic PTFE) Membrane Sample preparation for ion chromatography HDPE 13 10 mL (≤ 25 µL) 0.20 156 0.45 25 100 mL (≤ 100 µL) 0.20 0.45 Non-sterile Millex® Syringe Filter with Fluoropore™ (Hydrophobic PTFE) Membrane Excellent solvent resistance HDPE 4 1 mL (≤10 µL) 0.20 155 0.45
Syringe Filters for HPLC & Sample Preparation | analytics
Pore Sizes and Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are used for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm, respectively.
SLFH02502 - Tank Vent Filter Millex-FH, 25 mm, PTFE, 0.45 µm
Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions.
Hydrophilic Ptfe at Thomas Scientific
Hydrophilic PTFE syringe filters have broad chemical compatibility and high pH resistance and are optically clear when wet with water. They are versatile filters for use with aqueous and aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation.
MilliporeSigma 13mm Nonsterile Millex Syringe Filters
Description. Hydrophobic PTFE membranes have excellent solvent resistance and are ideal for HPLC sample preparation; Overmolded polypropylene housing design provides a more robust filter, with a maximum housing pressure of 150psig (10 bar) enabling solutions to be filtered faster
Millipore PTFE Filter | Sigma-Aldrich
This 33 mm syringe filter with a Hydrophilic PTFE membrane, for non-sterile filtration on the Samplicity G2 system, has a 0.45 µm pore size used in preparation of aqueous & organic solutions prior to chromatography or other instrument analyses. Millipore
Hplc Syringe Filter - Autosampler Vial, Hplc Vial, PTFE
13mm Welded PTFE Hydrophilic Syringe Filter 0.22um. C0000282. 13mm Welded PTFE Hydrophilic Syringe Filter 0.45um. C0000283. 25mm Welded PTFE Hydrophilic Syringe Filter 0.22um. C0000284. 25mm Welded PTFE Hydrophilic Syringe Filter 0.45um. C0000289. 13mm Welded PVDF Hydrophilic Syringe Filter 0.22um. C0000290. 13mm Welded PVDF Hydrophilic Syringe
Wholesale Price of Millipore Membrane Filter - MeticLab
Membrane Filter is used in sample preparation prior to the analysis by using an instrumental analytical method such HPLC. We can provide to you different sizes and materials of the filter paper. The common diameter is 47mm and 50mm, and the following is 13mm, 25mm, and 60mm, other size is available too.
13mm 0.22um Hydrophilic Ptfe Polypropylene Syringe Filter For
13mm 0.22um Hydrophilic Ptfe Polypropylene Syringe Filter For Hplc Vial , Find Complete Details about 13mm 0.22um Hydrophilic Ptfe Polypropylene Syringe Filter For Hplc Vial,13mm 0.22um Hydrophilic Ptfe Syringe Filter,Hydrophilic Polypropylene Syringe Filter,Syringe Filter For Hplc Vial from Other Lab Supplies Supplier or Manufacturer-Zhejiang Aijiren Technologies Co., Ltd.
Difference between hydrophilic and hydrophobic filters
Hydrophobic filters are best suited for gas filtration, low surface tension solvents, and venting. In certain applications, hydrophobic filters are used to filter aqueous solutions because of compatibility requirements. Water or aqueous solutions can also pass through a hydrophobic filter once the water breakthrough pressure is reached.
Syringe Filters for HPLC and UHPLC
Cronus 4mm, 0.2µm PTFE syringe filter. Lowest Extractables. Luer Lock inlet, Luer Spike outlet. PTFE is a hydrophobic membrane and chemically resistant to virtually all solvents. It can be used for working with aggressive media such as strong acids and bases; Ideal for use with samples of <2ml; Retention volume: <7.5µl . Download brochure
Millipore Syringe Filter - Autosampler Vial, Hplc Vial, PTFE
1) Description. PTFE syringe filter with the highest chemical compatibility rating, strong chemical stability and inertia ,strong hydrophobicity ,suitable for the clarification of organic solvents. Recommended for HPLC and GC samples, sterilisation and clarification of most solvents and filtration of gases and air for venting. Ref.No. Description.